To enable PortFast on an interface:<br />

Task Command Syntax Command Mode<br />

Enable PortFast on an interface. spanning-tree stp-id portfast<br />

[bpduguard]<br />

Verify that PortFast is enabled on a port using <strong>the</strong> show spanning-tree command from <strong>the</strong> EXEC privilege<br />

mode or <strong>the</strong> show config command from INTERFACE mode; <strong>Force10</strong> recommends using <strong>the</strong> show<br />

config command, as shown in Figure 273.<br />

R1#(conf-if-gi-1/1)#show conf<br />

!<br />

interface GigabitE<strong>the</strong>rnet 1/1<br />

no ip address<br />

switchport<br />

spanning-tree 0 portfast<br />

no shutdown<br />

R1#(conf-if-gi-1/1)#<br />

Figure 273 PortFast Enabled on Interface<br />

INTERFACE<br />

Indicates that <strong>the</strong> interface is in PortFast mode<br />

<strong>FTOS</strong> <strong>Configuration</strong> <strong>Guide</strong>, version 7.7.1.0 393