Figure 502 Viewing Offline Diagnostics Test Results (continued)<br />

Test 107 - NVRAM Address Line test .................................. PASS<br />

Test 108 - NVRAM Data Line Test ..................................... PASS<br />

Test 110 - NVRAM Read Write test .................................... PASS<br />

.Test 111 - FLASH Write Read test .................................... PASS<br />

Test 112 - FPGA Registers Verification Test ......................... PASS<br />

Test 113 - FPGA Level1 Test ......................................... PASS<br />

Test 114 - FPGA Data bus walking 0 and 1's test ..................... PASS<br />

Test 115 - Temp/volt monitor write read test ........................ PASS<br />

Test 116 - Reg verification test POE manager 1 ...................... NOT APPL<br />

Test 117 - Reg verification test POE manager 2 ...................... NOT APPL<br />

Test 118 - Reg verification test POE manager 3 ...................... NOT APPL<br />

Test 119 - Reg verification test POE manager 4 ...................... NOT APPL<br />

Test 120 - EEPROM write read test ................................... PASS<br />

Test 122 - Blinking Status LEDs Test ................................ PASS<br />

Test 123 - PHY MGT DEV 0 Level1 Test ................................ PASS<br />

Test 124 - PHY IPC DEV 2 level1 Test ................................ PASS<br />

Test 125 - PHY IPC DEV 3 level1 Test ................................ PASS<br />

Test 126 - Local Eeprom MFG block checksum test ..................... PASS<br />

Test 127 - Local Eeprom SW block checksum test ...................... PASS<br />

Test 128 - 3.3 V Brick Load test .................................... PASS<br />

Test 129 - 2.5 V Brick Load test .................................... PASS<br />

Test 130 - 1.5 V Brick Load test .................................... PASS<br />

Test 131 - 1.25 V Brick Load test ................................... PASS<br />

Test 132 - 1.8 V Brick Load test .................................... PASS<br />

Test 133 - XFP Verification Test 0 .................................. PASS<br />

Test 134 - XFP Verification Test 1 .................................. PASS<br />

Test 135 - XFP Verification Test 2 .................................. PASS<br />

Test 136 - XFP Verification Test 3 .................................. PASS<br />

Test 137 - XFP Verification Test 4 .................................. NOT APPL<br />

Test 138 - XFP Verification Test 5 .................................. NOT APPL<br />

Test 139 - XFP Verification Test 6 .................................. NOT APPL<br />

Test 140 - XFP Verification Test 7 .................................. NOT APPL<br />

************** LEVEL 2 DIAGNOSTICS*********************************<br />

Test 200 - MAC MGT DEV 0 Level2 Test ................................ PASS<br />

Test 201 - MAC IPC DEV 0 Level2 Test ................................ PASS<br />

Test 202 - MAC IPC DEV 1 Level2 Test ................................ PASS<br />

Test 203 - PHY MGT DEV 0 Level2 Test ................................ PASS<br />

Test 204 - PHY IPC DEV 0 Level2 Test ................................ PASS<br />

Test 205 - PHY IPC DEV 1 Level2 Test ................................ PASS<br />

Test 216 - F10-SFM Port wise Traffic Test with PHY Loopback ......... PASS<br />

Test 218 - LCM SNAKE Test using CPU Traffic with MAC Loopback ....... PASS<br />

Test 219 - LCM SNAKE Test using CPU Traffic with PHY Loopback ....... PASS<br />

Test 220 - LCM Port wise Traffic Test using CPU traffic - MAC Loopbac PASS<br />

Test 221 - LCM Port wise Traffic Test using CPU traffic - PHY Loopbac PASS<br />

Test 222 - POE I2C Interface stress test on Unit - 0 ................ NOT APPL<br />

Test 223 - POE I2C Interface stress test on Unit - 1 ................ NOT APPL<br />

Test 224 - POE I2C Interface stress test on Unit - 2 ................ NOT APPL<br />

Test 225 - POE I2C Interface stress test on Unit - 3 ................ NOT APPL<br />

*********** FORCE10 C series Diagnostics END******************************<br />

Number of Diagnostics per<strong>for</strong>med 69<br />

Number of Diagnostics failed 0<br />

End of Diags<br />

Duration of execution: 3 min 18 sec<br />

-------------------------------------------------------------------<br />

<strong>Force10</strong>#<br />

710 C-<strong>Series</strong> Debugging and Diagnostics