Monitoring Hardware Components Via SNMP<br />

The SNMP traps and OIDs in Table 77 provide in<strong>for</strong>mation on C-<strong>Series</strong> hardware components.<br />

Table 77 SNMP Traps and OIDs<br />

OID String OID Name Description<br />

RPM<br />

.1.3.6.1.4.1.6027.3.1.1.3.8 chRPMMajorAlarmStatus Fault status of <strong>the</strong> major alarm LED on <strong>the</strong><br />

RPM<br />

.1.3.6.1.4.1.6027.3.1.1.3.9 chRPMMinorAlarmStatus Fault status of <strong>the</strong> minor alarm LED on <strong>the</strong><br />

RPM<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.11 chAlarmRpmUp Trap generated when <strong>the</strong> status of primary or<br />

secondary RPM changes to up and running<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.12 chAlarmRpmDown Trap generated when <strong>the</strong> status of primary or<br />

secondary RPM changes to down, ei<strong>the</strong>r by<br />

software reset or by being physically removed<br />

from <strong>the</strong> chassis<br />

Line Card<br />

.1.3.6.1.4.1.6027.3.1.1.2.3.1.15 chSysCardOperStatus Operational status of <strong>the</strong> card.<br />

• If <strong>the</strong> chSysCardAdminStatus is up, <strong>the</strong><br />

valid state is ready—<strong>the</strong> card is present and<br />

ready and <strong>the</strong> chSysCardOperStatus status<br />

is up.<br />

• If <strong>the</strong> chSysCardAdminStatus is down <strong>the</strong><br />

service states can be:<br />

• offline: <strong>the</strong> card is not used.<br />

• cardNotmatch: <strong>the</strong> card does not<br />

match what is configured<br />

• cardProblem: a hardware<br />

problem has been detected on <strong>the</strong><br />

card.<br />

• diagMode: <strong>the</strong> card is in <strong>the</strong><br />

diagnostic mode.<br />

Note: chSysCardFaultStatus is supported only<br />

<strong>the</strong> C-<strong>Series</strong>.<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.1 chAlarmCardDown Trap reported when a card operational status<br />

changes to down<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.2 chAlarmCardUp Trap reported when a card operational status<br />

changes to up<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.3 chAlarmCardReset Trap reported when a card is reset<br />

.1.3.6.1.4.1.6027.3.1.1.4.0.7 chAlarmCardProblem Trap reported when a card operational status<br />

changes to card problem<br />

.1.3.6.1.4.1.6027.3.1.1.1.4.0.5 chAlarmCardMismatch Trap generated when <strong>the</strong> configured card does<br />

not match <strong>the</strong> installed card<br />

.1.3.6.1.4.1.6027.3.1.1.1.4.0.6 chAlarmCardRemove Trap generated when a card is removed<br />

704 C-<strong>Series</strong> Debugging and Diagnostics