Step Task Command Command Mode<br />

3 Upgrade <strong>the</strong> boot code on <strong>the</strong> standby RPM.<br />

using <strong>the</strong> keyword rpm.<br />

Specify <strong>the</strong> location of <strong>the</strong> <strong>FTOS</strong> image that<br />

contains <strong>the</strong> bootflash image to which you are<br />

upgrading.<br />

Figure 506 Viewing <strong>the</strong> Boot Code Version on RPMs<br />

Figure 507 Viewing <strong>the</strong> Boot Code Version on Line Cards<br />

upgrade bootflash-image rpm<br />

file-url<br />

EXEC Privilege<br />

4 Exit <strong>the</strong> Telnet session with <strong>the</strong> standby RPM. exit EXEC Privilege<br />

5 When <strong>the</strong> upgrade process is complete, you<br />

can leave <strong>the</strong> system as is. The new boot code<br />

loads upon <strong>the</strong> next power-cycle of <strong>the</strong> RPM or<br />

system. You can also reset <strong>the</strong> RPM<br />

immediately to see if <strong>the</strong> boot code<br />

downloaded successfully.<br />

6 Verify that <strong>the</strong> upgrade is successful, as<br />

shown in Figure 506 <strong>for</strong> RPMs and Figure 507<br />

<strong>for</strong> line cards.<br />

<strong>Force10</strong># show rpm 1<br />

Status : standby<br />

Next Boot : online<br />

Card Type : RPM - Route Processor Module (LC-EF-RPM)<br />

Hardware Rev : 2.0<br />

Num Ports : 1<br />

Up Time : 36 wk, 4 day, 1 hr, 11 min<br />

Last Restart : reset by user<br />

<strong>FTOS</strong> Version : 6.1.2.4<br />

Jumbo Capable : yes<br />

CP Boot Flash : A: 2.4.0.9 [booted] B: 2.4.0.9<br />

RP1 Boot Flash: A: 2.4.0.9 [booted] B: 2.4.0.9<br />

RP2 Boot Flash: A: 2.4.0.9 [booted] B: 2.4.0.9<br />

<strong>Force10</strong>#show line 1<br />

-- Line card 1 --<br />

Status : online<br />

Next Boot : online<br />

Required Type : E48PF - 48-port GE line card with SFP optics (EF)<br />

Current Type : E48PF - 48-port GE line card with SFP optics (EF)<br />

Hardware Rev : Base - 1.0 PP0 - 1.1 PP1 - 1.1<br />

Num Ports : 48<br />

Up Time : 47 min, 48 sec<br />

<strong>FTOS</strong> Version : 4.4.3.498<br />

Jumbo Capable : yes<br />

Boot Flash : A: 2.3.0.9 B: 2.3.0.9 [booted]<br />

Memory Size : 268435456 bytes<br />

Temperature : 44C<br />

Power Status : PEM0: absent or down PEM1: up<br />

Voltage : ok<br />

Serial Number : 0017179<br />

Part Number : 7520014310 Rev 03<br />

Vendor Id : 04<br />

Date Code : 02472004<br />

Country Code : 01<br />

reset rpm hard EXEC Privilege<br />

show {rpm | linecard} EXEC Privilege<br />

722 Upgrade Procedures