Chapter 8 Port Monitoring<br />

Port Monitoring is supported on plat<strong>for</strong>ms: c e s<br />

Port Monitoring is a feature that copies all incoming or outgoing packets on one port and <strong>for</strong>wards <strong>the</strong>m to<br />

to ano<strong>the</strong>r port. The source port is <strong>the</strong> monitored port (MD) and <strong>the</strong> destination port is <strong>the</strong> monitoring port<br />

(MG). Port Monitoring functionality is different between plat<strong>for</strong>ms, but <strong>the</strong> behavior is <strong>the</strong> same, with<br />

highlighted exceptions.<br />

This chapter is divided into <strong>the</strong> following sections:<br />

• Port Monitoring on E-<strong>Series</strong> on page 175<br />

• Port Monitoring on C-<strong>Series</strong> and S-<strong>Series</strong> on page 176<br />

• Important Points to Remember on page 177<br />

• Configuring Port Monitoring on page 177<br />

• Flow-based Monitoring on page 179 — e<br />

Port Monitoring on E-<strong>Series</strong><br />

On <strong>the</strong> E-<strong>Series</strong>, <strong>FTOS</strong> supports a single source-destination statement in a monitor session (Message 9).<br />

<strong>FTOS</strong> allows only one source and one destination port per port-pipe (Message 10). There<strong>for</strong>e, <strong>the</strong> E-<strong>Series</strong><br />

supports as many monitoring sessions as <strong>the</strong>re are port-pipes in <strong>the</strong> system.<br />

Message 9 Multiple Source-Destination Statements Error Message on E-<strong>Series</strong><br />

% Error: Remove existing monitor configuration.<br />

Message 10 One Source/Destination Port per Port-pipe Error Message on E-<strong>Series</strong><br />

% Error: Some port from this port pipe is already configured as MD.<br />

% Error: Some port from this port pipe is already configured as MG.<br />

A source port may only be monitored by one destination port (Message 11). However, a destination port<br />

may monitor more than one source port. Given <strong>the</strong>se parameters, Figure 86 illustrates conceptually <strong>the</strong><br />

possible port monitoring configurations on <strong>the</strong> E-<strong>Series</strong>.<br />

Message 11 One Destination Port per Source Port Error Message<br />

% Error: MD port is already being monitored.<br />