<strong>Force10</strong>#show redundancy<br />

-- RPM Status --<br />

------------------------------------------------<br />

RPM Slot ID: 1<br />

RPM Redundancy Role: Primary<br />

RPM State: Active<br />

Link to Peer: Up<br />

-- PEER RPM Status --<br />

------------------------------------------------<br />

RPM State: Standby<br />

-- RPM Redundancy <strong>Configuration</strong> --<br />

------------------------------------------------<br />

Primary RPM: rpm0<br />

Auto Data Sync: Full<br />

Failover Type: Hot Failover<br />

Auto reboot RPM: Enabled<br />

Auto failover limit: 3 times in 60 minutes<br />

-- RPM Failover Record --<br />

------------------------------------------------<br />

Failover Count: 1<br />

Last failover timestamp: Dec 13 2003 21:25:32<br />

Last failover Reason: User request<br />

-- Last Data Block Sync Record: --<br />

------------------------------------------------<br />

Line Card Config: succeeded Dec 13 2003 21:28:53<br />

Start-up Config: succeeded Dec 13 2003 21:28:53<br />

SFM Config State: succeeded Dec 13 2003 21:28:53<br />

Runtime Event Log: succeeded Dec 13 2003 21:28:53<br />

Running Config: succeeded Dec 13 2003 21:28:53<br />

<strong>Force10</strong>#<br />

Figure 257 show redundancy Command Example<br />

synchronize data between two RPMs<br />

By default, all data between <strong>the</strong> two RPMs is synchronized directly after boot-up. You have several options<br />

to synchronize data between <strong>the</strong> RPMs.<br />

• clock<br />

• preferred primary RPM configuration (redundancy primary command)<br />

• boot in<strong>for</strong>mation<br />

• management port IP address in<strong>for</strong>mation<br />

Displays <strong>the</strong> RPM’s role, ei<strong>the</strong>r as <strong>the</strong><br />

primary or secondary.<br />

Once <strong>the</strong> two RPMs have done an initial full synchronization, <strong>the</strong>reafter <strong>FTOS</strong> only updates changed data.<br />