Show debounce times in an interface<br />

show interface debounce [type]<br />

[slot/port]<br />

Figure 184 Showing .Debounce Time<br />

<strong>Force10</strong>#<br />

<strong>Force10</strong>#show interfaces debounce gigabite<strong>the</strong>rnet 3/1<br />

Interface Time(ms)<br />

GigabitE<strong>the</strong>rnet 3/1 200<br />

<strong>Force10</strong>#<br />

Disabling ports when one only SFM available (E300 only)<br />

Selected ports can be shut down when a single SFM is available on <strong>the</strong> E300 system. Each port to be shut<br />

down must be configured individually.<br />

When an E300 system boots up and a single SFM is active this configuration, any ports configured with<br />

this feature will be shut down. All o<strong>the</strong>r ports are booted up.<br />

Similarly, if an SFM fails (or is removed) in an E300 system with two SFM, ports configured with this<br />

feature will be shut down. All o<strong>the</strong>r ports are treated normally.<br />

When a second SFM is installed or replaced, all ports are booted up and treated as normally. This feature<br />

does not take affect until a single SFM is active in <strong>the</strong> E300 system.<br />

Disable port on one SFM<br />

EXEC Privilege Show <strong>the</strong> debounce time fpr <strong>the</strong> specified interface.<br />

Enter <strong>the</strong> interface type keyword followed by <strong>the</strong><br />

type of interface and slot/port in<strong>for</strong>mation:<br />

• For a 10/100/1000 E<strong>the</strong>rnet interface, enter<br />

<strong>the</strong> keyword GigabitE<strong>the</strong>rnet followed by <strong>the</strong><br />

slot/port in<strong>for</strong>mation.<br />

• For a Gigabit E<strong>the</strong>rnet interface, enter <strong>the</strong><br />

keyword GigabitE<strong>the</strong>rnet followed by <strong>the</strong> slot/<br />

port in<strong>for</strong>mation.<br />

• For a 10 Gigabit E<strong>the</strong>rnet interface, enter <strong>the</strong><br />

keyword TenGigabitE<strong>the</strong>rnet followed by <strong>the</strong><br />

slot/port in<strong>for</strong>mation.<br />

Note: <strong>FTOS</strong> rounds <strong>the</strong> entered debounce time up to <strong>the</strong> nearest hundredth. Note in<br />

Figure 183 <strong>the</strong>timer was set at 150 ms, but appears as 200 in Figure 184.<br />

This feature must be configured to each interface you wish to shut down in <strong>the</strong> case of SFM disabling.<br />

Command Syntax Command Mode Purpose<br />

disable-on-sfm-failure INTERFACE Disables <strong>the</strong> port when a single SFM only is<br />

available.<br />

280 Interfaces