15.01.2013 Views

ATLAS 550 System Manual - Adtran

ATLAS 550 System Manual - Adtran

ATLAS 550 System Manual - Adtran

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Section 4 User Interface Guide <strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong><br />

MODULES (E1/PRA-1) > PERFORMANCE CURRENT<br />

Write security: 5; Read security: 5<br />

The performance fields (either current, 15-minute total, or 24-hour total) provide status on key<br />

performance measures as specified in G.821 and RFC 1406 for the E1/PRA port as follows:<br />

PRT Displays the port number<br />

CLR Clears performance information for the selected port<br />

ES Errored Second (ES) is a second with one or more error events OR one or more Out<br />

Of Frame events OR one or more Controlled Slips<br />

BES Bursty Errored Second (BES) is a second with more than one, but less than 320 error<br />

events<br />

SES Severely Errored Second (SES) is a second with 320 or more error events OR one or<br />

more Out Of Frame events<br />

UAS Unavailable Second is a second in which the E1 was not available for use (due to<br />

outage, alarms, etc.).<br />

CSS Controlled Slip Second<br />

SEFS Severely Errored Frame Second is a second that contains four consecutive errored<br />

framing patterns<br />

DM Degraded Minutes is the number of minutes with a bit error rate of 10 -6 or greater<br />

LCV Line Code Violation indicates a mismatch in line coding somewhere in the network<br />

and is determined by receiving an invalid line violation (bipolar violation).<br />

PCV Path Code Violation is a received error in the frame synchronization bit (for non<br />

CRC framing) or a CRC error (CRC framing).<br />

LES Line Errored Second is a second in which an error was received on the T1.<br />

LOFC Loss of Frame Count is a count of seconds in which a valid framing pattern could not<br />

be obtained<br />

MODULES ((E1/PRA-1) > PERFORMANCE 15MIN<br />

Write security: 5; Read security: 5<br />

Stores the performance data for the previous 15-minute window. Refer to Modules (E1/PRA-1) ><br />

Performance Current for a detailed description of these fields.<br />

MODULES (E1/PRA-1) > PERFORMANCE 24HR<br />

Write security: 5; Read security: 5<br />

Stores the performance data for the previous 24-hour window. Refer to Modules (E1/PRA-1) ><br />

Performance Current for a detailed description of these fields.<br />

MODULES (E1/PRA-1) > CONFIGURATION<br />

Write security: 5; Read security: 5<br />

All of the following configurable parameters apply whether the port is connected to a Primary Rate Access<br />

circuit or a channelized E1 circuit.<br />