15.01.2013 Views

ATLAS 550 System Manual - Adtran

ATLAS 550 System Manual - Adtran

ATLAS 550 System Manual - Adtran

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong> Section 4 User Interface Guide<br />

MODULES (NXT1HSSI) > CONFIGURATION > PORT<br />

Read security: 5<br />

Displays the operating port number. There are four available T1 ports on the NxT1 HSSI and NxT1<br />

HSSI/V.35 Option Modules.<br />

MODULES (NXT1HSSI) > CONFIGURATION > PORT NAME<br />

Write security: 3; Read security: 5<br />

Accepts any alpha-numeric name up to 16 characters long, to uniquely identify each T1 port on the NxT1<br />

HSSI and NxT1 HSSI/V.35 Option Modules.<br />

MODULES (NXT1HSSI) > CONFIGURATION > FRAME<br />

Write security: 2; Read security: 5<br />

This field must be set to match the frame format of the circuit to which it is connected, available from the<br />

network supplier. Choose either D4 or ESF.<br />

MODULES (NXT1HSSI) > CONFIGURATION > CODE<br />

Write security: 2; Read security: 5<br />

Set this field to match the line code of the circuit to which it is connected (this information is available<br />

from the network supplier). Choose either AMI (Alternate Mark Inversion) or B8ZS (Bipolar Eight Zero<br />

Substitution).<br />

MODULES (NXT1HSSI) > CONFIGURATION > TX YEL<br />

Write security: 3; Read security: 5<br />

Controls the transmission of yellow alarms. Choose either ON or OFF.<br />

MODULES (NXT1HSSI) > CONFIGURATION > LBO<br />

Write security: 2; Read security: 5<br />

Selects the Line Build Out (LBO) for the network interface. When connecting an <strong>ATLAS</strong> <strong>550</strong> port to a<br />

DSX-1 interface, this parameter is typically set to match the distance (in feet) between the <strong>ATLAS</strong> <strong>550</strong> and<br />

the device with which it is connecting. When you select this item, a list of choices displays (0 dB, -7.5 dB,<br />

-15 dB, -22 dB, 266 FT, 399 FT, 533 FT, 655 FT). Select the appropriate option.<br />

MODULES (NXT1HSSI) > TEST<br />

Write security: 5; Read security: 5<br />

These options initiate different types of tests and display test results.<br />

MODULES (NXT1HSSI) > TEST > PORT<br />

Read security: 5<br />

Displays the operating port number. There are four available T1 interfaces on the NxT1 HSSI and NxT1<br />

HSSI/V.35 Option Modules.<br />

61200305L2-1B © 2004 ADTRAN, Inc. 165