Section 4 User Interface Guide <strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong><br />

MODULES (DBU) > BRI TEST > LOCAL LOOPBACK<br />

Write security: 3; Read security: 5<br />

Activates a local loopback of the BRI U interface toward the network. The following options are available:<br />

NONE No active loopback<br />

LOOPBACK B1 Loops the first B channel of the interface<br />

LOOPBACK B2 Loops the second B channel of the interface<br />

LOOPBACK B1 & B2 Loops both B channels of the interface<br />

LOOPBACK ALL Loops the entire physical interface (2B + D)<br />

MODULES MENU (DUAL/QUAD T1/PRI OPTION MODULES)<br />

This section provides detailed information on the MODULES menu and submenus for the Dual/Quad T1/PRI<br />

Option Modules. The <strong>ATLAS</strong> <strong>550</strong> system controller automatically detects the presence of the Dual/Quad<br />

T1/PRI Option Modules when they are installed in the system (Dual is listed as T1/PRI-2 and the Quad is<br />

listed as T1/PRI-4). All menus detailed in this section that apply to both modules are listed as T1/PRI-2/4.<br />

To see the menus for the Dual/Quad T1/PRI Option Modules via the terminal menu, use the arrow keys to<br />

scroll to the MODULES menu and press to access the module choices. Refer to the Dual/Quad<br />

T1/PRI Option Modules Quick Start Guide for a menu tree containing a complete listing of menus.<br />

MODULES (T1/PRI-2/4) > INFO<br />

Read security: 5<br />

Displays general information about the T1/PRI Network Interface Module as follows:<br />

MODULES (T1/PRI-2/4) > INFO > PART NUMBER<br />

Read security: 5<br />

Displays the part number of the T1/PRI Network Interface Module.<br />

MODULES (T1/PRI-2/4) > INFO > SERIAL NUMBER<br />

Read security: 5<br />

Displays the module’s serial number.<br />

MODULES (T1/PRI-2/4) > INFO > ASSEMBLY REVISION<br />

Read security: 5<br />

Displays the assembly revision of the module.<br />

MODULES (T1/PRI-2/4) > INFO > PLL STATUS<br />

Read security: 5<br />

Indicates whether the module phase lock loop is locked to its specific source.<br />