<strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong> Section 4 User Interface Guide<br />

MODULES (USSI-2) > TEST > LOOPBACK<br />

Write security: 4; Read security: 5<br />

Test pattern to be transmitted out the port. The following options are available:<br />

NO LOOPBACK No active loopback.<br />

LOCAL LOOPBACK Activates both a local loopback (back toward the DTE) and a port<br />

loopback (toward the network).<br />

REMOTE LOOPBACK V.54 loopback code to be sent to the far end, and if the device at the far<br />

end supports V.54, the device activates a loopback on detection of the<br />

V.54 code.<br />

MODULES (USSI-2) > TEST > LOOPBACK STATUS<br />

Read security: 5<br />

This read-only option indicates a port’s current loopback status by displaying any of the following status<br />

messages:<br />

NO LOOPBACK ACTIVE REMOTE LOOP-UP FAILED<br />

LOOPING UP REMOTE UNIT PORT LOOPED FROM REMOTE SOURCE<br />

REMOTE UNIT LOOPED BACK PORT LOOPBACK ACTIVE<br />

LOOPING DOWN REMOTE UNIT<br />

MODULES (USSI-2) > TEST > 511<br />

Write security: 4; Read security: 5<br />

Controls the activation of the 511 test pattern generator and detector.<br />

MODULES (USSI-2) > TEST > 511 RESULT<br />

Read security: 5<br />

Displays the results of the 511 test. This option is read-only. Clear these results by pressing when<br />

CLR is selected.<br />

NONE Pattern is not synchronized.<br />

LOS At one point the pattern was synchronized, but is currently not<br />

synchronized.<br />

SYNC Pattern is synchronized.<br />

ES Number of seconds with at least one bit error.<br />

MODULES (USSI-2) > TEST > INJECT<br />

Write security: 4; Read security: 4<br />

Injects errors into transmitted test pattern.<br />

MODULES (USSI-2) > TEST > CLR<br />

Write security: 4; Read security: 4<br />

Clears error counters on test pattern results menu.<br />

61200305L2-1B © 2004 ADTRAN, Inc. 141