Section 6 CFG-1 <strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong><br />

5. Configure the IFCE CONFIG options for the backup link. These include the Dial Backup parameters.<br />

Navigate to the IFCE CONFIG option and press . This action displays a list of the Dial Backup<br />

options. (The options are described following the figure.)<br />

)<br />

ORIGINATE/ANSWER<br />

ORIGINATE: The <strong>ATLAS</strong> <strong>550</strong> will be the originating side in the event of a failure.<br />

ANSWER: The <strong>ATLAS</strong> <strong>550</strong> will answer any incoming calls, but only go into backup if an<br />

error is detected.<br />

ANSWER ALWAYS: The <strong>ATLAS</strong> <strong>550</strong> will answer any incoming calls and immediately go into backup.<br />

OUTGOING CALL TYPE<br />

SOURCE ID<br />

DIGITAL 56K: Data rate for the backup endpoint is set to 56kbps.<br />

DIGITAL 64K: Data rate for the backup endpoint is set to 64kbps.<br />

The SOURCE ID should remain in the default state unless it has been assigned elsewhere in the<br />

configuration. Please refer to the User Interface Guide beginning on page 63 for a detailed<br />

discussion of the SOURCE ID field.<br />

OUTDIAL NUMBER<br />

This field should contain the number you want the <strong>ATLAS</strong> <strong>550</strong> to dial upon going into backup.<br />

FORCE MODE<br />

AUTO: The <strong>ATLAS</strong> <strong>550</strong> will automatically follow the dial backup configuration<br />

parameters to go into backup.<br />

FORCED: The <strong>ATLAS</strong> <strong>550</strong> must be manually forced to go into backup upon detection of a<br />

failure.<br />

DISABLED: The <strong>ATLAS</strong> <strong>550</strong> will never go into backup regardless of data integrity.<br />

362 © 2004 ADTRAN, Inc. 61200305L2-1B