Section 5 DLP-12 <strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong><br />

Perform the following steps in the order listed.<br />

1. Mount the modem in its permanent position.<br />

2. Connect power to the modem using manufacturer instructions.<br />

3. Configure the modem as follows:<br />

Speed 9600 bps<br />

Data bits 8<br />

Parity none<br />

Stop bits 1<br />

Flow control hardware<br />

Auto answer on<br />

DTR ignore<br />

4. Connect the data cable’s male RJ-45 connector to the ADMIN port’s female RJ-45 connector. (The<br />

DB-9 CRAFT interface on the front of the unit is not modem-capable.)<br />

5. Route the data cable to the modem.<br />

6. Connect the other end of the data cable to the RJ-45 end of the supplied connector (Female RJ-45 to<br />

Male DB-25). Then connect the DB-25 end of the connector to the modem, configured as in step 3.<br />

7. Connect the modem to the POTS line as required by the manufacturer.<br />

8. Log in to the <strong>ATLAS</strong> <strong>550</strong> system. (Refer to DLP-2, Logging in to the <strong>ATLAS</strong> <strong>550</strong>, for detailed<br />

instructions).<br />

9. From the MAIN MENU, select the SYSTEM CONFIG menu and press the right-arrow key to enter the<br />

right-pane menus.<br />

10. From the SYSTEM CONFIG menu, select the CHAIN PORT menu and press . Once in the CHAIN<br />

PORT menus, press the right-arrow key to enter the right-pane menus.<br />

11. From the CHAIN PORT menus, select the PORT TYPE menu and select DIAL.<br />

If you are connected to the <strong>ATLAS</strong> <strong>550</strong> using the CRAFT or ADMIN interfaces,<br />

changing the PORT TYPE mode to DIAL will terminate your session. You MUST have<br />

Ethernet access to the <strong>ATLAS</strong> <strong>550</strong> to change the PORT TYPE back to DIRECT and<br />

restore your terminal session.<br />

To complete the connection to the unit, the <strong>ATLAS</strong> <strong>550</strong> must now be called from a PC<br />

configured to emulate a VT100 terminal, with communication software set as in step 3 and<br />

configured for DIAL mode.<br />

340 © 2004 ADTRAN, Inc. 61200305L2-1B