<strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong> Section 4 User Interface Guide<br />

DIAL PLAN (CKT BACKUP) > USER TERM > IFCE CONFIG > FORCE MODE<br />

Write security: 3; Read security: 5<br />

This forces the backup state of this endpoint. This is a configuration setting, so it will retain its value until<br />

it is changed. To temporarily force an endpoint into backup, or to force a restore, try the <strong>Manual</strong> activator.<br />

DIAL PLAN (CKT BACKUP) > USER TERM > IFCE CONFIG > BACKUP CRITERIA<br />

Write security: 3; Read security: 5<br />

Criteria for automatic backup. Note that this setting affects the available options for RESTORE CRITERIA.<br />

NET/DATA FAIL DBU is initiated when either the network fails (possible causes include Red,<br />

Yellow, Blue, or LOS alarms) or when the Nx56/64 module detects a loss of<br />

data transitions on the V.35 interface. If Net/Data Fail is selected, the V.35 Nx<br />

INBAND option must be ON. The remote TSU INBAND option must also be<br />

enabled.<br />

When BACKUP CRITERIA is configured for NET/DATA FAIL, the RESTORE CRITERIA must be<br />

MANUAL ONLY.<br />

NET FAIL DBU is initiated when there is a network failure. Possible causes include<br />

LOS, RED, Yellow, or Blue alarms.<br />

MANUAL The <strong>ATLAS</strong> will never initiate DBU until it is manually set to do so.<br />

DIAL PLAN (CKT BACKUP) > USER TERM > IFCE CONFIG > RESTORE CRITERIA<br />

Write security: 3; Read security: 5<br />

This only applies to originating endpoints. These are criteria for automatically coming out of backup. Note<br />

that NETWORK SUCCESS is only available when a backup criterion is not NET/DATA FAIL.<br />

NET SUCCESS When network is out of alarm<br />

MANUAL ONLY Only by the <strong>Manual</strong> activator<br />

DIAL PLAN (CKT BACKUP) > USER TERM > IFCE CONFIG > STARTUP DELAY<br />

Write security: 3; Read security: 5<br />

The amount of time to wait after creating or changing the endpoint before allowing backup.<br />

DIAL PLAN (CKT BACKUP) > USER TERM > IFCE CONFIG > BACKUP DELAY<br />

Write security: 3; Read security: 5<br />

The amount of time to delay after detecting an alarm before going into backup. This only applies to<br />

originating endpoints. If the circuit comes out of alarm before this time has expired, the endpoint will not<br />

go into backup.<br />