<strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong> Section 4 User Interface Guide<br />

MODULES (U-BRI-4) > TEST > LOCAL LOOPBACK<br />

Write security: 4; Read security: 5<br />

Activates a local loopback of the U interface toward the network. The following options are available:<br />

NONE No active loopback.<br />

LOOPBACK B1 Loops the first B channel of the interface.<br />

LOOPBACK B2 Loops the second B channel of the interface.<br />

LOOPBACK B1 & B2 Loops both B channels of the interface.<br />

LOOPBACK 2B+D Loops the entire physical interface.<br />

MODULES MENU (QUAD BASIC RATE ISDN (S/T INTERFACE) OPTION MODULE)<br />

The <strong>ATLAS</strong> <strong>550</strong>0 system controller automatically detects the presence of the Quad BRI (S/T Interface)<br />

Option Module when it is installed in the system (listed as ST-BRI-4). To see the menus for the Quad BRI<br />

(S/T Interface) Option Module via the terminal menu, use the arrow keys to scroll to the MODULES menu<br />

and press to access the module choices. Refer to the Quad BRI (S/T Interface) Option Module<br />

Quick Start Guide for a menu tree containing a complete listing of menus.<br />

MODULES (ST-BRI-4) > INFO<br />

Write security: 5; Read security: 5<br />

Provides information about the module part number, serial number, and assembly revision.<br />

MODULES (ST-BRI-4) > INFO > PART NUMBER<br />

Read security: 5<br />

Displays the part number of the module.<br />

MODULES (ST-BRI-4) > INFO > SERIAL NUMBER<br />

Read security: 5<br />

Displays the serial number of the module.<br />

MODULES (ST-BRI-4) > INFO > ASSEMBLY REVISION<br />

Read security: 5<br />

Displays the assembly revision of the installed module.<br />

MODULES (ST-BRI-4) > ALARMS<br />

Write security: 5; Read security: 5<br />

Displays the alarm status for each S/T interface on the installed module.<br />

MODULES (ST-BRI-4) > ALARMS > PRT<br />

Write security: 5; Read security: 5<br />

Indicates the port number. There are 4 available interfaces on the Quad BRI-S/T Option Module.<br />