<strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong> Section 4 User Interface Guide<br />

SYSTEM CONFIG > BONDING CONFIG > TANULL TIMER<br />

Write security: 3; Read security: 5<br />

Specifies the length of time the answering endpoint attempts to detect the BONDING negotiation pattern<br />

from the originating endpoint before deciding the BONDING call has failed. It may be necessary to<br />

shorten this timer if the DTE equipment using the BONDING module also has timer constraints for<br />

completing non-BONDING parameter negotiation.<br />

SYSTEM CONFIG > BONDING CONFIG > TCID TIMER<br />

Write security: 3; Read security: 5<br />

Specifies the length of time both endpoints attempt to negotiate an agreeable value for bearer channels (B<br />

channels) and channel capacities before deciding the BONDING call has failed.<br />

SYSTEM CONFIG > BONDING CONFIG > CALL STAGGER<br />

Write security: 3; Read security: 5<br />

Specifies the amount of delay between placing calls for outgoing BONDING sessions. The following call<br />

stagger values are available: NO STAGGER, 500 MS, 1 SEC, and 2 SEC<br />

SYSTEM CONFIG > ALARM RELAY RESET<br />

Write security: 3; Read security: 5<br />

Clears the Alarm Relay located on the back panel of the <strong>ATLAS</strong> <strong>550</strong>. Activating the software Alarm Relay<br />

Reset functions the same as manually pressing the ACO switch located on the <strong>ATLAS</strong> <strong>550</strong> front panel.<br />

SYSTEM CONFIG > ALARM RELAY THRESHOLD<br />

Write security: 3; Read security: 5<br />

Defines which threshold sets the Alarm Relay. These thresholds include CRITICAL, MAJOR, MINOR,<br />

WARNING, and NORMAL. If an alarm occurs that is greater than or equal to the threshold selected, the Alarm<br />

Relay will set. For example, if the threshold is set for MAJOR, then ALL MAJOR alarms and ALL CRITICAL<br />

alarms will set the Alarm Relay. There is one exception – setting the threshold to NORMAL will not set the<br />

Alarm Relay for NORMAL events. No NORMAL events set the Alarm Relay.<br />