<strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong> Section 4 User Interface Guide<br />

MODULES (ST-BRI-4) > CONFIGURATION > LINE TERMINATION<br />

Write security: 3; Read security: 5<br />

Termination resistors in both the transmit and receive paths (100 Ω) are required (per CCITT I.430, ETSI<br />

ETS 300012, and ANSI T1.605) for all BRI S/T interfaces operating in NT mode (User Term) and TE<br />

mode (Network Term) in point-to-point applications. ANSI T1.605 provides examples of S/T interfaces<br />

configured in a multi-point NT1 star operation. The NT1 star mode allows a single NT device to support<br />

multiple T interfaces (TE devices). Custom cables are required for this type of application, and are not<br />

available for purchase (from ADTRAN) for the <strong>ATLAS</strong> <strong>550</strong>.<br />

This parameter should be left in the default state for most applications.<br />

MODULES (ST-BRI-4) > CONFIGURATION > PS1 LINE POWER<br />

Write security: 3; Read security: 5<br />

The <strong>ATLAS</strong> <strong>550</strong> is capable of providing 1W (at 40 V) power on each BRI S/T interface to provide line<br />

power (phantom power) to TE equipment. Set this parameter to ON only if the TE equipment connected to<br />

the S/T interface requires line power.<br />

MODULES (ST-BRI-4) > TEST<br />

Write security: 5; Read security: 5<br />

These options initiate different types of tests and display test results.<br />

MODULES (ST-BRI-4) > TEST > PRT<br />

Write security: 5; Read security: 5<br />

Identifies the port number. There are 4 available interfaces on the Quad BRI-S/T Option Module.<br />

MODULES (ST-BRI-4) > TEST > LOCAL LOOPBACK<br />

Write security: 4; Read security: 5<br />

Do not enable line power on a BRI S/T interface configured for TE mode (Network<br />

Term). Setting this parameter to ON in a TE configuration (Network Term) may result<br />

in damage to the module.<br />

Activates a local loopback toward the S/T interface. The following options are available:<br />

NONE No active loopback.<br />

LOOPBACK B1 Loops the first B channel of the interface.<br />

LOOPBACK B2 Loops the second B channel of the interface.<br />

LOOPBACK B1 + B2 Loops both B channels of the interface.<br />

LOOPBACK 2B + D Loops the entire physical interface (both bearer channels and the data<br />

channel).<br />