Section 5 DLP-15 <strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong><br />

Perform the following steps below in the order listed:<br />

1. Connect to the <strong>ATLAS</strong> <strong>550</strong> using either the ETHERNET, ADMIN, or CRAFT interfaces.<br />

If you are not already connected to the unit’s ADMIN or CRAFT interface, either with a VT100<br />

compatible terminal or with a PC running VT100 emulation software, use the procedure in DLP-2,<br />

Logging in to the <strong>ATLAS</strong> <strong>550</strong>, to connect to the ADMIN or CRAFT interface.<br />

Alternatively, if the unit is part of a management cluster connected to the local network, you may use a<br />

PC connected to the network to Telnet into the unit. To connect to the ETHERNET interface, use the<br />

procedures in DLP-3, Setting IP Parameters for the <strong>ATLAS</strong> <strong>550</strong>, and in DLP-4, Verifying<br />

Communications Over an IP LAN.<br />

2. Log in to the unit using the read-write password (see DLP-2, Logging in to the <strong>ATLAS</strong> <strong>550</strong>, for details).<br />

Configuring the Alarm Relay<br />

1. Go to the SYSTEM CONFIG menu and press the right-arrow key to access the right-pane menus. Select<br />

the ALARM RELAY THRESHOLD menu and choose the appropriate threshold level. The ALARM RELAY<br />

will set for this threshold and all other alarms of greater importance. Refer to Section 7, <strong>System</strong> Event<br />

Logging of this user manual for a listing of all alarms and levels of importance.<br />

Setting the threshold to NORMAL will not set the ALARM RELAY for NORMAL events. No<br />

NORMAL events set the ALARM RELAY.<br />

(Optional) Configuring the Alarm Monitor for External Alarms<br />

1. Go to the SYSTEM CONFIG menu and press the right-arrow key to access the right-pane menus. Then,<br />

select the EVENT LOGGING menu and press . Once in the EVENT LOGGING menu, press the<br />

right-arrow key to access the right-pane menus.<br />

2. From the EVENT LOGGING menu, select the EXTERNAL INPUT menu and set it to the same value as the<br />

ALARM RELAY THRESHOLD. Any event on the ALARM MONITOR will now be logged in the EVENT LOG and<br />

set the ALARM RELAY.<br />

Clearing the Alarm Relay Remotely<br />

1. Go to the SYSTEM CONFIG menu and press the right-arrow key to access the right-pane menus. Then,<br />

select the ALARM RELAY RESET field and press .<br />

Clear the ALARM RELAY locally by pressing the ACO switch on the front panel.<br />

350 © 2004 ADTRAN, Inc. 61200305L2-1B