<strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong> Section 2 Engineering Guidelines<br />

4. REVIEWING THE BACK PANEL DESIGN<br />

AC <strong>System</strong><br />

The <strong>ATLAS</strong> <strong>550</strong> (AC <strong>System</strong>) back panel contains four slots for housing option modules which provide a<br />

variety of additional resources and data ports. All slots are functionally identical. The <strong>ATLAS</strong> <strong>550</strong> also<br />

contains two slots for housing network modules (see Figure 2).<br />

ALL EMPTY SLOTS MUST BE<br />

COVERED WITH BLANK PANELS<br />

500 Series<br />

500 Series<br />

Figure 2. <strong>ATLAS</strong> <strong>550</strong> (AC <strong>System</strong>) Back Panel<br />

DC <strong>System</strong><br />

The <strong>ATLAS</strong> <strong>550</strong> (DC <strong>System</strong>) back panel contains four slots for housing option modules which provide a<br />

variety of additional resources and data ports. All slots are functionally identical. The <strong>ATLAS</strong> <strong>550</strong> also<br />

contains two slots for housing network modules (see Figure 3).<br />

ALL EMPTY SLOTS MUST BE<br />

COVERED WITH BLANK PANELS<br />

1<br />

2<br />

1<br />

2<br />

NETWORK 1<br />

NETWORK 1<br />

Option<br />

Module Slots<br />

500 Series<br />

3<br />

4<br />

NETWORK 2<br />

Figure 3. <strong>ATLAS</strong> <strong>550</strong> (DC <strong>System</strong>) Back Panel<br />

O I<br />

61200305L2-1B © 2004 ADTRAN, Inc. 31<br />

500 Series<br />

500 Series<br />

500 Series<br />

ADMIN<br />

Power<br />

Switch<br />

90-240VAC, 2A 50/60Hz<br />

FUSE RATING: 2A/250V SLO-BLO<br />

ETHERNET<br />

RELAY ALARM<br />

Network Module Slots ADMIN 10/100BaseT<br />

Port Ethernet<br />

Option<br />

Module Slots<br />

500 Series<br />

500 Series<br />

500 Series<br />

3<br />

4<br />

NETWORK 2<br />

500 Series<br />

Network Module Slots ADMIN<br />

Port<br />

500 Series<br />

500 Series<br />

ADMIN<br />

Power<br />

Switch<br />

MON NC NO COM<br />

O I<br />

+ Ð<br />

INPUT:<br />

FUSE:<br />

24Ð48V ,4A<br />

5A/48VDC<br />

USE COPPER CONDUCTORS ONLY<br />

ETHERNET<br />

RELAY ALARM<br />

10/100BaseT<br />

Ethernet<br />

MON NC NO COM<br />

CAUTION: FOR CONTINUED PROTECTION<br />

AGAINST RISK OF FIRE, REPLACE ONLY<br />

WITH SAME TYPE AND RATING OF FUSE.<br />

AC Power<br />

Connection<br />

Alarm<br />

Relay<br />

Connection<br />

External Alarm<br />

Relay Connection<br />

CAUTION: FOR CONTINUED PROTECTION<br />

AGAINST RISK OF FIRE, REPLACE ONLY<br />

WITH SAME TYPE AND RATING OF FUSE.<br />

DC Power<br />

Connection<br />

Alarm<br />

Relay<br />

Connection<br />

External Alarm<br />

Relay Connection