DLP-15 Using the Alarm Connections and the ACO Button<br />

Introduction<br />

Alarm connections alert the user when a selected alarm condition exists. Pressing the Alarm Cut-Off<br />

(ACO) switch on the front panel of the <strong>ATLAS</strong> <strong>550</strong> clears the alarm. This procedure details the steps which<br />

must be performed to use the <strong>ATLAS</strong> <strong>550</strong> alarm connections and the ACO switch.<br />

This procedure should be performed at installation on each <strong>ATLAS</strong> <strong>550</strong> shelf that is wired out to external<br />

office alarm equipment.<br />

Prerequisite Procedures<br />

Before beginning this procedure, the <strong>ATLAS</strong> <strong>550</strong> should be mounted in its permanent location and the<br />

alarm contacts should be connected (see DLP-14, Connecting the Alarm Contacts).<br />

Tools and Materials Required<br />

• VT100 terminal or PC with VT100 terminal emulation software<br />

To prevent electrical shock, do not install equipment in a wet location or during a<br />

lightning storm.<br />

Electronic equipment can be damaged by static electrical discharge. Before handling it,<br />

put on an antistatic discharge wrist strap to prevent damage to electronic components.<br />

Place equipment in antistatic packing material when transporting or storing. When<br />

working on equipment, always place it on an approved antistatic mat that is electrically<br />

grounded.<br />

61200305L2-1B © 2004 ADTRAN, Inc. 349