Section 5 DLP-7 <strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong><br />

Perform the following steps in the order listed.<br />

1. Connect to the <strong>ATLAS</strong> <strong>550</strong> using the back panel’s RJ-48 ADMIN interface or the front panel’s DB-9<br />

CRAFT interface.<br />

If you are not already connected to the unit’s ADMIN or CRAFT interface (either with a VT100<br />

compatible terminal or with a PC running VT100 emulation software), follow the procedure in DLP-1,<br />

Connecting a VT100 Terminal or PC to the ADMIN or CRAFT Port. Connecting to the ADMIN or<br />

CRAFT interface limits the upgrade procedure to XMODEM only.<br />

2. Log in to the unit using the read-write password (see DLP-2, Logging in to the <strong>ATLAS</strong> <strong>550</strong> for details).<br />

3. Go to the SYSTEM UTILITY menu and select the UPDATE FIRMWARE menu; press .<br />

4. Select the MODULE SLOT menu and press .<br />

Select the appropriate module slot to update. Select SLOT 0 to update the system controller.<br />

Selecting ALL MODULES OF A TYPE and SYS CTRL will force a controller reboot during the<br />

update.<br />

5. Go to the TRANSFER METHOD menu and select XMODEM.<br />

6. From the RESTART SCHEDULE menu, select the time for the module to perform a restart after<br />

completing the update process.<br />

RESTART IMMEDIATELY AFTER UPDATE restarts the system immediately after the update is complete.<br />

RESTART AT SPECIFIED DATE AND TIME allows you to select when the updated system will restart. If<br />

you select this option, a new field called RESTART DATE AND TIME displays below the current field.<br />

To use that option, enter the time in 24-hour format (such as 23:00:00 for 11:00 pm). Enter the date in<br />

mm-dd-yyyy format (for example, 09-30-2000).<br />

7. View CURRENT UPDATE STATUS to verify the progress of the current firmware update or to identify any<br />

errors encountered during the download.<br />

8. Select BEGIN FIRMWARE UPDATE to start the update. Enter Y to confirm the transfer and set up the<br />

module to receive the XMODEM upload.<br />

When the <strong>ATLAS</strong> <strong>550</strong> is ready to receive the XMODEM upload, the menu screen will clear and<br />

display Awaiting XMODEM Upload.... twice to Cancel. If this does not appear, please<br />

review the steps above for possible configuration errors.<br />

9. From the terminal emulation software, begin the XMODEM upload by using the appropriate command<br />

sequence. This may take several minutes.<br />

If necessary, refer to the terminal emulation software documentation for help. Also, when specifying<br />

the filename, ensure that the file transferred is the one provided by ADTRAN. Otherwise, the update<br />

will not complete successfully.<br />

Because XMODEM data is being transferred inband through the menu interface, the VT100 menus of<br />

the <strong>ATLAS</strong> <strong>550</strong> will be inoperable from the ADMIN or CRAFT interfaces. You can cancel the update at<br />

any time within the terminal emulation software. (Please consult the documentation provided by the<br />

terminal emulation software to determine how to do this).<br />