<strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong> Section 2 Engineering Guidelines<br />

External Alarm Relay Monitor Connection<br />

This connection alerts the user when a selected external alarm condition exists. This connection could be<br />

used to monitor a UPS with dry contacts or another <strong>ATLAS</strong> <strong>550</strong>. The 2-pin, removable terminal block<br />

connects with external wiring. Refer to DLP-14, Connecting the Alarm Contacts, for detailed instructions.<br />

Clear the alarm condition by pressing the ACO switch located on the front panel of the <strong>ATLAS</strong> <strong>550</strong>.<br />

Table 6 shows the pinout for the External Alarm Relay connector.<br />

Alarm Relay Connection<br />

Table 6. External Relay Monitor Connector Pinout<br />

Pin Name Description<br />

1 ALARM OUT Outputs EIA-232 level signal for connection to external alarm contacts.<br />

2 ALARM IN Monitors signal coming from external alarm contacts.<br />

This connection alerts the user when a selected alarm condition exists. The 4-pin, removable terminal<br />

block connects with external wiring. Refer to DLP-14, Connecting the Alarm Contacts, for detailed<br />

instructions. Clear the alarm condition by pressing the ACO switch located on the front panel of the<br />

<strong>ATLAS</strong> <strong>550</strong>. Table 7 shows the pinout for the Alarm Relay connector.<br />

Table 7. Alarm Relay Connector Pinout<br />

Pin Name Description<br />

1 NORMALLY CLOSED (NC) Opens when a selected alarm condition is present.<br />

2 NORMALLY OPEN (NO) Closes when a selected alarm condition is present.<br />

3 COMMON (COM)<br />

4 CHASSIS GROUND (GND) Ground connection.<br />

Common connection between external circuitry and NC or NO<br />

terminal.<br />

5. NETWORK INTERFACE MODULES<br />

The <strong>ATLAS</strong> <strong>550</strong> provides two Network Interface Slots that allow different types of interfaces to be used.<br />

Available Network Interface Modules include the following:<br />

• T1/PRI Network Interface Module (P/N 1200307L1/L2), USOC RJ-48C. (See page 34.)<br />

• E1/PRA Network Interface Module (P/N 1200308L1), 15-pin female D-connector. (See page 34.)<br />

• Modem Management Network Module (P/N 1200341L1), USOC RJ-11C. (See page 35.)<br />

• BRI DBU Network Module (P/N 1200327L1), USOC RJ-49C. (See page 36.)<br />