Section 4 User Interface Guide <strong>ATLAS</strong> <strong>550</strong> <strong>System</strong> <strong>Manual</strong><br />

MODULES (ST-BRI-4) > ALARMS > ALARMS<br />

Write security: 5; Read security: 5<br />

Displays the current alarm status of each BRI S/T interface.<br />

L1 DOWN A layer one alarm is indicated by an asterisk (*) when the BRI S/T<br />

physical layer is not active. An L1 alarm is present when problems are<br />

detected with the endpoint or a cabling problem.<br />

MODULES (ST-BRI-4) > ALARMS > CHANNEL<br />

Write security: 5; Read security: 5<br />

Displays the alarm status of the bearer (B) channels and the datalink (D) channel. A hyphen (–) indicates<br />

no active channel alarm and D indicates an active D channel alarm.<br />

MODULES (ST-BRI-4) > CHANNEL USAGE<br />

Read security: 5<br />

Displays the channel status of the bearer (B) channels and the datalink (D) channel for each BRI S/T<br />

interface.<br />

MODULES (ST-BRI-4) > CHANNEL USAGE > PRT<br />

Write security: 5; Read security: 5<br />

Indicates the port number. There are 4 available interfaces on the Quad BRI-S/T Option Module.<br />

MODULES (ST-BRI-4) > CHANNEL USAGE > CHA<br />

Write security: 5; Read security: 5<br />

(Channel) Displays the status of individual channels. The following symbols may display:<br />

- Unallocated channel<br />

. Inactive channel<br />

A Active B channel<br />

D Active D channel<br />

MODULES (ST-BRI-4) > CONFIGURATION<br />

Write security: 5; Read security: 5<br />

Allows the user to personally identify each port with an appropriate name.<br />

MODULES (ST-BRI-4) > CONFIGURATION > PRT<br />

Write security: 5; Read security: 5<br />

Displays the port number. There are 4 available interfaces on the Quad BRI-S/T Option Module.<br />

MODULES (ST-BRI-4) > CONFIGURATION > PORT NAME<br />

Write security: 3; Read security: 5<br />

Accepts any alpha-numeric name up to 16 characters long, to uniquely identify each port on the Octal BRI<br />

S/T Option Module.<br />