Agilent splitless liners<br />

Single taper splitless liner<br />

Single taper, glass wool splitless liner<br />

Double taper splitless liner<br />

Direct Connect liners<br />

Agilent Splitless Liners<br />

www.agilent.com/chem/supplies<br />

Inlet Liners<br />

Agilent's proprietary deactivation is important for splitless liners because of the longer<br />

sample/liner contact time in splitless mode.<br />

When deciding between a liner with or without glass wool, choose a liner without glass wool<br />

if your sample contains non-volatiles or analytes within a wide boiling range. For unknown<br />

samples, use a liner without glass wool to avoid loss of active or labile compounds. Agilent<br />

recommends first trying a liner without glass wool; use glass wool as a second choice.<br />

Agilent Splitless Liners<br />

Description 1/pk 5/pk 25/pk<br />

Single taper, deactivated 5181-3316 5183-4695 5183-4696<br />

Single taper, inert 5181-3316i<br />

Single taper, glass wool, deactivated 5062-3587 5183-4693 5183-4694<br />

Single taper, MS certified liner with glass wool 5188-6568<br />

Double taper, deactivated 5181-3315 5183-4705 5183-4706<br />

Straight, deactivated, quartz 5181-8818 5183-4703 5183-4704<br />

Straight, non-deactivated, quartz 18740-80220 5183-4707 5183-4708<br />

Straight, non-deactivated 210-3003 210-3003-5<br />

Direct Connect Liners<br />

Agilent's Direct Connect Liners provide maximum recovery and minimal decomposition of<br />

active compounds for methods requiring splitless injection, such as EPA 8270. They are best<br />

for relatively clean samples containing active analytes, such as water extracts. The liners<br />

directly connect with the column, similar to press-fit connectors, to aid complete transfer<br />

of sample onto the column, eliminating the problem of inlet discrimination and further<br />

increasing sensitivity.<br />

Direct Connect Liners<br />

Description Part No.<br />

Single taper, Agilent proprietary deactivation G1544-80730<br />

Dual taper, Agilent proprietary deactivation G1544-80700<br />

Single taper, deactivated, inert G1544-80731<br />

GC and GC/MS<br />

155