10.09.2013 Views

TABLE OF CONTENTS - BGB Analytik AG

TABLE OF CONTENTS - BGB Analytik AG

TABLE OF CONTENTS - BGB Analytik AG

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ASTM Methods<br />

Method<br />

Designation Method Title Column Recommendation Part No.<br />

D 5917 Standard Test Method for Trace Impurities in<br />

Monocyclic Aromatic Hydrocarbons by GC<br />

and External Calibration<br />

D 5974 Standard Test Method for Fatty and Rosin Acids in<br />

Tall Oil Fraction Products by Capillary GC<br />

D 5986 Standard Test Method for Determination of<br />

Oxygenates, Benzene, Toluene, C8-C12 Aromatics and<br />

Total Aromatics in Finished Gasoline by GC/FTIR<br />

D 6144 Standard Test Method for Trace Impurities in<br />

Alpha-Methylstyrene by Capillary GC<br />

D 6159 Standard Test Method for Determination of<br />

Hydrocarbon Impurities in Ethylene by GC<br />

D 6160 Standard Test Method for Determination of PCBs in<br />

Waste Materials by GC<br />

D 6352 Standard Test Method for Boiling Range Distribution<br />

of Petroleum Distillates in Boiling Range from 174<br />

to 700 by GC<br />

D 6417 Standard Test Method for Estimation of Engine Oil<br />

Volatility by Capillary GC<br />

D 2360 Standard Test Method for Trace Impurities in<br />

Monocyclic Aromatic Hydrocarbons by GC<br />

E 1616 Standard Test Method for Analysis of Acetic<br />

Anhydride Using GC<br />

E 1863 Standard Test Method for Analysis of Acrylonitrile<br />

by GC<br />

E 202 Standard Test Method for Analysis of Ethylene<br />

Glycols and Propylene Glycols<br />

E 475 Standard Test Method for Assay of Di-tert-Butyl<br />

Peroxide Using GC<br />

GC Column Application and Method Guides<br />

HP-INNOWax<br />

60 m x 0.32 mm, 0.25 µm<br />

DB-23<br />

60 m x 0.25 mm, 0.25 µm<br />

HP-1<br />

60 m x 0.53 mm, 5.00 µm<br />

HP-1<br />

60 m x 0.25 mm, 1.00 µm<br />

HP-PLOT Al2O3 "KCl"<br />

50 m x 0.53 mm, 15.00 µm<br />

GS-Alumina<br />

50 m x 0.53 mm<br />

DB-1<br />

50 m x 0.53 mm<br />

HP-5MS<br />

30 m x 0.32 mm, 0.25 µm<br />

DB-XLB<br />

30 m x 0.25 mm, 0.25 µm<br />

DB-HT SimDis<br />

5 m x 0.53 mm, 0.15 µm<br />

DB-HT SimDis<br />

5 m x 0.53 mm, 0.15 µm<br />

HP-INNOWax<br />

60 m x 0.32 mm, 0.25 µm<br />

HP-1<br />

50 m x 0.32 mm, 0.52 µm<br />

DB-WAXetr<br />

60 m x 0.32 mm, 1.00 µm<br />

DB-624<br />

30 m x 0.53 mm, 3.00 µm<br />

HP-5<br />

30 m x 0.53 mm, 5.00 µm<br />

Tips & Tools<br />

www.agilent.com/chem/supplies<br />

19091N-116<br />

122-2362<br />

19095Z-626<br />

19091Z-236<br />

19095P-K25<br />

115-3552<br />

125-1035<br />

19091S-413<br />

122-1232<br />

145-1001<br />

145-1001<br />

19091N-116<br />

19091Z-115<br />

123-7364<br />

125-1334<br />

19095J-623<br />

Gain extra confidence to meet high standards with Agilent's solution for the revised<br />

USP . Visit www.agilent.com/chem/usp467an.<br />

GC and GC/MS<br />

349

Hooray! Your file is uploaded and ready to be published.

Saved successfully!