10.09.2013 Views

TABLE OF CONTENTS - BGB Analytik AG

TABLE OF CONTENTS - BGB Analytik AG

TABLE OF CONTENTS - BGB Analytik AG

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Featured Products<br />

Featured Products<br />

Performance Electronics<br />

6,250 u/sec<br />

7.60 7.62<br />

7.64<br />

More Signal<br />

Standard Electronics<br />

6,250 u/sec<br />

7.66<br />

7.68<br />

7.55 7.60 7.65 7.70<br />

0.84 sec width<br />

half height<br />

10,000 u/sec<br />

The Agilent 5975C Series MSD<br />

with the New Triple-Axis Detector<br />

Proven performance, superior productivity – and maximum confidence<br />

in your results<br />

4 www.agilent.com/chem/supplies<br />

Over 30 years of innovation and leadership have led to a total GC/MS solution for your lab.<br />

Better MS resolution, the industry’s lowest mass deviation, superior sensitivity in all ionization<br />

modes and unquestioned spectral integrity establish a solid foundation of consistent quality for<br />

all of your GC/MS applications.<br />

• Inert ion source – now programmable up to 350˚C – delivers enhanced response for active<br />

compounds and late eluters<br />

• True hyperbolic quadrupole – maximum transmission and resolution<br />

• Thermally stable quartz quadrupole – the proprietary quadrupole can be heated up to<br />

200°C for long-term mass axis stability<br />

• The Triple-Axis Detector with the triple-channel electron multiplier increases signal and<br />

reduces neutral noise for even lower detection limits<br />

• 0.10 µ mass axis stability over 48 hours – ensures longer lasting tune and calibration stability<br />

• Auto CI – automatic EPC reagent gas adjustment and CI tuning<br />

• Electron impact (EI) ionization standard with CI ion source – obtain EI and CI spectra from<br />

the same source<br />

• Fast SIM – dwell time as short as 1 ms<br />

• 1050 µ mass range – extends application space for high mass compounds<br />

• Ammonia specification for PCI/NCI – unique to the industry<br />

• SemiQuant capability – easy and fast estimation of amount of unknown compounds<br />

Fast electronics enhance full scan and SIM performance<br />

Agilent's 5975C Series GC/MSD includes performance electronics to maximize signal<br />

transmission for faster GC/MS in full scan, Selected Ion Monitoring (SIM) and Synchronous<br />

SIM/Scan modes.<br />

• Scan rates up to 12,500 µ/s – compatible with fast full scan GC/MS<br />

• Run Synchronous SIM/Scan without compromising performance<br />

• More data points per peak – for better peak integration

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!