Silica Support<br />

C18<br />

C18<br />

Novel Bidentate C18-C18 Bonding for Extend C-18<br />

Bonded Phase<br />

ZORBAX 80Å Extend-C18<br />

www.agilent.com/chem/supplies<br />

ZORBAX 80Å Extend-C18<br />

• High efficiency and long life at high pH – up to pH 11.5<br />

• Unique bidentate bonding and double endcapping provides high pH stability<br />

• More efficiency and better peak shape than polymer-based columns<br />

• Improve retention, resolution and peak shape of basic compounds<br />

• High sensitivity for LC/MS separations of peptides<br />

The Agilent ZORBAX Extend-C18 column uses a novel bidentate C18-C18 bonding technology<br />

to make it possible to develop high-resolution separations at high pH with a silica-based<br />

column. At high pH, non-charged basic compounds will not interact with the underlying silica.<br />

The result is high efficiency separations with superior peak shape and improved resolution.<br />

High pH separations are also the best choice for compounds that are more stable or more<br />

soluble in high pH solutions. Some of the mobile phase buffer options for high pH include<br />

triethylamine, pyrrolidine, glycine, borate and ammonium hydroxide. Ammonium hydroxide at<br />

pH 10.5 is an excellent mobile phase modifier for the LC/MS of peptides and small molecules<br />

with improved sensitivity compared with TFA containing mobile phase at low pH. The Extend-<br />

C18 column is stable from pH 2-11.5 with good peak shape for all types of compounds.<br />

Extend-C18 columns also provide an additional selectivity choice at low pH.<br />

Column Specifications<br />

Pore Surface Temp. pH<br />

Carbon<br />

Bonded Phase Size Area Limits* Range** Endcapped Load<br />

ZORBAX Extend-C18 80Å 180 m2/g 60°C 2.0-11.5 Double 12.5%<br />

Specifications represent typical values only.<br />

*Temperature limits are 60°C up to pH 8, 40°C from pH 8-11.5.<br />

**Above pH 6 highest column stability for all silica based column is obtained by reducing the operating temperature to 40°C<br />

or below and using lower buffer concentrations (0.01 - 0.02M) or organic buffers.<br />

LC and LC/MS<br />

617