Environmental Applications, Pesticides and Herbicides<br />

CLP Pesticide Analysis<br />

Column: DB-XLB<br />

121-1222<br />

20 m x 0.18 mm, 0.18 µm<br />

Carrier: H2, constant flow, 77.3 cm/s at 120 °C<br />

Oven: 120°C for 0.49 min<br />

120°C to 160°C at 59.4°/min<br />

160°C to 260°C at 23.7°/min<br />

260°C to 300°C (1.69min) at 35.6°/min<br />

Injection: Pulsed Splitless, 220°C<br />

Pulse pressure & time: 35psi for 0.5 min Flow<br />

ramp at 6.25 min of 99 mL/min 2 to 3 mL/min<br />

2 mm ID liner<br />

Detector: µ-ECD, 320°C<br />

Ar/CH4 (P5) makeup gas at 60mL/min<br />

Sample: 0.5 µL, 50 ppb<br />

Column: DB-XLB<br />

123-1232<br />

30 m x 0.32 mm, 0.25 µm<br />

Carrier: He, constant flow, 38 cm/s at 120ºC<br />

Oven: 120ºC for 1.17 min<br />

120ºC to 160ºC at 25º/min<br />

160ºC to 260ºC at 10º/min<br />

260ºC to 300ºC (4 min) at 15º/min<br />

Injection: Pulsed Splitless, 220ºC<br />

Pulse pressure & time: 35 psi for 1.15 min<br />

Detector: µ-ECD, 320ºC<br />

Ar/CH4 (P5) makeup gas at 60 mL/min<br />

Sample: 2 µL, 50 ppb<br />

Environmental Applications, Pesticides and Herbicides<br />

Faster Method (using a High Efficiency GC Column and H2 carrier)<br />

3.6e + 07<br />

3.4e + 07<br />

3.2e + 07<br />

3e + 07<br />

2.8e + 07<br />

2.6e + 07<br />

2.4e + 07<br />

2.2e + 07<br />

2e + 07<br />

1.8e + 07<br />

1.6e + 07<br />

1.4e + 07<br />

1.2e + 07<br />

1e + 07<br />

8000000<br />

6000000<br />

4000000<br />

2000000<br />

1. TCMX<br />

2. Alpha BHC<br />

3. Gamma BHC<br />

4. Beta BHC<br />

5. Delta BHC<br />

6. Heptachlor<br />

7. Aldrin<br />

8. Heptachlor Epoxide<br />

9. Gamma Chlordane<br />

10. Alpha Chlordane<br />

11. Endosulfan I<br />

Original Method (using a 0.32 mm ID column and Helium carrier)<br />

1.9e + 08<br />

1.8e + 08<br />

1.7e + 08<br />

1.6e + 08<br />

1.5e + 08<br />

1.4e + 08<br />

1.3e + 08<br />

1.2e + 08<br />

1.1e + 08<br />

1e + 08<br />

9e + 07<br />

8e + 07<br />

7e + 07<br />

6e + 07<br />

5e + 07<br />

4e + 07<br />

3e + 07<br />

2e + 07<br />

1e + 07<br />

0.50<br />

www.agilent.com/chem/supplies<br />

1<br />

2<br />

3<br />

4<br />

Time (min)<br />

5, 6<br />

7<br />

8<br />

9 10<br />

12<br />

13<br />

11<br />

14 15<br />

1618<br />

1.00 1.50 2.00 2.50 3.00 3.50 4.00 4.50 5.00 5.50 6.00 6.50 7.00<br />

1<br />

2<br />

3<br />

4<br />

5, 6<br />

7<br />

Time (min)<br />

8<br />

1<br />

12. 4,4' DDE<br />

13. Dieldrin<br />

14. Endrin<br />

15. 4,4' DDD<br />

16. Endosulfan II<br />

17. 4,4' DDT<br />

18. Endrin Aldehyde<br />

19. Endosulfan Sulfate<br />

20. Methoxychlor<br />

21. Endrin Ketone<br />

22. DCB<br />

9 10<br />

12<br />

11 13<br />

14 15<br />

18<br />

16 19<br />

2.00 4.00 6.00 8.00 10.00 12.00 14.00 16.00<br />

Contract Laboratory Program (CLP) pesticide analysis on High Efficiency (0.18 mm I.D.) GC columns. In this example, the analysis of 22 CLP pesticides were achieved in 16<br />

minutes using the original method, whereas the improved method was completed in just under 7 minutes. That's a 56% faster sample run time.<br />

17<br />

20<br />

21<br />

17<br />

19<br />

20<br />

21<br />

22<br />

22<br />

GCHE006<br />

GCHE007<br />

GC and GC/MS<br />

361