ZORBAX Solvent Saver<br />

• Provide 60% reduction in mobile phase usage and waste generation compared to<br />

a 4.6 mm ID column<br />

• Provide 2- to 3-fold signal-to-noise (S/N ratio) improvement<br />

• Deliver optimal LC/MS performance at intermediate flow rates<br />

• Can be used with most conventional LC instrument configurations without modification<br />

• Solvent Saver columns are available in 1.8, 3.5 and 5 µm particle sizes<br />

Agilent ZORBAX Solvent Saver columns have a 3.0 mm internal diameter. This is ideal for<br />

reducing solvent usage by 50% over 4.6 mm ID columns. Solvent Saver columns are also<br />

ideal for LC/MS. With a typical flow rate of 0.5 ml/min, these columns are compatible with<br />

almost all LC interfaces. These columns also improve sensitivity 2 to 3 times over 4.6 mm ID<br />

columns. Solvent Saver columns can be used with conventional HPLC instruments and are a<br />

good choice for cost effective analyses.<br />

Solvent Saver Columns Provide up to 60% Reduction<br />

in Solvent Use and Waste<br />

Column A: ZORBAX SB-C18<br />

883975-902<br />

4.6 x 150 mm, 5 µm<br />

Column B: ZORBAX SB-C18<br />

883975-302<br />

3.0 x 150 mm, 5 µm<br />

Mobile Phase: 20% ACN: 80% 0.2 M Na2HPO4<br />

+ 0.1 M Citric Acid, pH 2.6<br />

Temperature: Ambient<br />

Sample: Antibacterials<br />

A B<br />

Less solvent consumption,<br />

less waste<br />

0<br />

1<br />

2<br />

3<br />

4<br />

5<br />

Time (min)<br />

www.agilent.com/chem/supplies<br />

6<br />

40<br />

0<br />

1<br />

2<br />

ZORBAX Solvent Saver<br />

3<br />

1. Sulfamerazine<br />

2. Furazolidone<br />

3. Oxolinic Acid<br />

4. Sulfadimethoxine<br />

5. Sulfaquinoxaline<br />

6. Nalidixic Acid<br />

4<br />

5<br />

Time (min)<br />

This separation of antibacterials on a 4.6 and 3.0 mm ID columns, shows that solvent use is reduced by 50% just by changing to the Solvent Saver column with no change<br />

in the chromatography. This reduces the cost of analyses dramatically.<br />

6<br />

40<br />

LCSS001<br />

LC and LC/MS<br />

651