GC and GC/MS<br />

308<br />

LTM Column Modules<br />

NEW!<br />

Agilent J&W LTM Column Modules<br />

• Suitable for majority of Agilent J&W Capillary GC columns (30 m maximum length)<br />

• Rapid temperature programming rates of up to 1800°C/min<br />

• Fast cooling times – less than one minute for some configurations<br />

• Excellent retention time repeatability, comparable to conventional GC<br />

• Ability to run up to four column modules simultaneously, using different<br />

temperature programs<br />

• Works with 7890/6890 GC injectors and detectors for little change to your<br />

existing methods<br />

• Compatible with Agilent Capillary Flow Technology, for multi-dimensional GC<br />

LTM column modules combine a fused silica capillary column with heating and temperature<br />

sensing components wound around it. The design heats and cools the column very efficiently<br />

for significantly shorter analytical cycle times compared to conventional air-bath GC oven<br />

techniques, while simultaneously using less power.<br />

LTM column modules are available in two column assembly sizes: 5 inch diameter (standard)<br />

and 3 inch diameter (small). The standard format provides faster cooling speeds than the<br />

small format. Since the chromatography quality is basically equivalent for the two module<br />

sizes, Agilent recommends the 5 inch (standard) configuration.<br />

When utilizing the 3 inch (small) configuration, up to four column modules can be installed<br />

per Agilent LTM system, enabling multidimensional GC applications. With the 5 inch (standard)<br />

configuration, two column modules can be installed per Agilent LTM system. Module sizes can<br />

be mixed so that one 5-inch column module can be used with either one or two 3 inch<br />

column modules.<br />

The majority of Agilent J&W Capillary GC columns can be used for LTM column modules,<br />

including Wall Coated Open Tubular (WCOT) columns and Porous Layer Open Tubular (PLOT)<br />

columns. Any capillary GC column with column length up to 30 meters can be put into the<br />

5 inch format. The 3 inch format is limited to capillary GC columns with column inner<br />

diameters (ID) of 0.32 mm or smaller. The 3 inch format is not recommended for PLOT<br />

columns or any capillary column that is known to be especially fragile.<br />

All LTM column modules come standard with the following:<br />

• Two 1 meter guard columns (deactivated fused silica tubing) of the same internal diameter<br />

as the analytical column, one each for inlet and detector<br />

• Package of five non-reusable ferrules that are appropriate for the dimensions of the guard<br />

columns and analytical columns<br />