GC and GC/MS<br />

220<br />

Agilent J&W GC and GC/MS Columns<br />

The Tightest QC Specs in the Business<br />

Agilent makes more capillary GC columns than anyone else in the world, and we build them to meet consistently rigid performance criteria,<br />

such as separation efficiency, retention characteristics, peak height ratios, and bleed rates.<br />

Agilent's stringent QC performance evaluation tests provide the utmost confidence in the qualitative and quantitative results, especially<br />

for difficult-to-chromatograph compounds. We measure peak height ratios for acidic and basic compounds to ensure the highest column<br />

performance for the widest range and types of compounds. We also carefully monitor peak symmetry and tailing for a broad range of<br />

chemically active compounds.<br />

Tighter GC Column Performance Criteria<br />

Feature Advantage Benefit<br />

Narrow Retention Index<br />

Highest level of column-to-column Confidence in analytical results<br />

and Retention Factor Window<br />

reproducibility<br />

Minimal method adjustment when Improved sample throughput,<br />

changing columns<br />

reduced downtime<br />

Specify J&W chemistry for intra-company Confidence in method transfer<br />

methodologies<br />

and intra-company results<br />

Increased Plates per Meter Highest level of "resolving power" Accurate quantification<br />

Improved sample throughput<br />

Potentially shorter run times<br />

Lowest Bleed Increased analytical sensitivity Improved detection limits<br />

for all detectors<br />

Reliable compound identification<br />

Fast baseline stabilization<br />

Minimized conditioning time<br />

Faster column exchange<br />

Increased sample throughput<br />

Excellent thermal stability Increased column lifetime,<br />

reduced downtime<br />

Increased sample throughput<br />

Highest Degree of Inertness Better peak shape for active compounds Improved detection limit, more<br />

Minimum compound adsorption<br />

accurate quantification, and more<br />

instrument uptime<br />

More accurate quantification for trace<br />

samples and unknown sample screening<br />

Tips & Tools<br />

For additional column recommendations, chromatograms, and method<br />

parameters, visit www.agilent.com/chem/mygccol1<br />

www.agilent.com/chem/supplies