GC and GC/MS<br />

164<br />

Column Connectors/Splitters<br />

Graphpak connector for Agilent capillary detectors<br />

Graphpak divider for simultaneous sampling<br />

Capillary injection port connector, 5021-7170<br />

Column 1<br />

Detector 1<br />

Column<br />

Injector<br />

Transfer Line<br />

Splitter Union<br />

Column 2<br />

Fixed inlet splitter<br />

Detector 2<br />

Transfer Lines<br />

Splitter Union<br />

Fixed Outlet Splitter<br />

Inlet<br />

Variable outlet splitter, 5181-3393<br />

Graphpak Capillary Column Connectors (2.5 mm)*<br />

Column ID (mm) Connector ID (mm) Part No.<br />

Capillary Detector Port Connector<br />

0.32/0.25 0.4 5021-7166<br />

0.32/0.25 0.7 5021-7164<br />

Capillary Divider for Simultaneous Sampling<br />

0.32/0.25 0.53 5021-7148<br />

0.53 0.7 5021-7146<br />

Capillary Injection Port Connector<br />

0.2 0.3 5021-7169<br />

0.32/0.25 0.4 5021-7170<br />

0.53 0.7 5021-7168<br />

*The 2.5 mm Graphpak is not compatible with the Graphpak 2M used for the PTV.<br />

Note: Order ferrules in addition to the connector to fit your column. Ferrules must be<br />

ordered separately.<br />

Ferrules for Connectors<br />

Column ID (mm) ID (mm) Unit Part No.<br />

0.2 0.3 10/pk 5021-7136<br />

0.32/0.25 0.4 10/pk 5021-7137<br />

0.53 0.7 10/pk 5021-7134<br />

Graphpak plug ferrule 10/pk 5021-7133<br />

Replacement Graphpak column nut 5/pk 5062-3525<br />

Capillary Column Splitters<br />

Description<br />

Fixed Inlet Splitter<br />

Tubing ID (mm) Part No.<br />

0.22 5181-3390<br />

0.32 5181-3391<br />

Fixed Outlet Splitter<br />

0.53 5181-3392<br />

1:1 ratio splitter 0.22 to 0.22 0101-0594<br />

1:5 ratio splitter 0.22 to 0.15 5181-3389<br />

1:10 ratio splitter<br />

Two-hole replacement ferrules, 10/pk<br />

0.21 to 0.11 0101-0595<br />

0.30 5181-3388<br />

0.4 5062-3580<br />

Variable Outlet Splitter<br />

0.5 5062-3581<br />

Variable outlet system<br />

5181-3393<br />

Includes metal body and 5 meter 0.22 mm ID transfer line with 0.4 mm 2-hole ferrule<br />