13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

2Installing a <strong>Brocade</strong> <strong>MLX</strong>e-8 routerFIGURE 56The <strong>Brocade</strong> <strong>MLX</strong>e-8 DC power supply2DC INDC OUT ALM1 Screws holding transparent cover 2 Power lug screws12. Use a #2 Phillips screwdriver to remove the power lugs.3. Crimp #8 AWG power supply wire into the power lugs <strong>and</strong> reconnect the lugs to the powersupply unit. Refer to Figure 57.CAUTIONFor the NEBS-compliant installation of <strong>Brocade</strong> <strong>MLX</strong>e-4, <strong>Brocade</strong> <strong>MLX</strong>e--8, <strong>and</strong> <strong>Brocade</strong> <strong>MLX</strong>e-16routers with AC <strong>and</strong> DC systems, use a ground wire of at least 6 American Wire Gauge (AWG). Theground wire should have an agency-approved crimped connector (provided with the device)attached to one end, with the other end attached to building ground. The connector must becrimped with the proper tool, allowing it to be connected to both ground screws on the enclosure.Before crimping the ground wire into the provided ground lug, ensure the bare copper wire hasbeen cleaned <strong>and</strong> antioxidant is applied to the bare wire.CAUTIONFor the NEBS-compliant installation of <strong>Brocade</strong> <strong>MLX</strong>e-32, routers with AC <strong>and</strong> DC systems, use aground wire of at least 2 American Wire Gauge (AWG). The ground wire should have anagency-approved crimped connector (provided with the device) attached to one end, with theother end attached to building ground. The connector must be crimped with the proper tool,allowing it to be connected to both ground screws on the enclosure. Before crimping the groundwire into the provided ground lug, ensure the bare copper wire has been cleaned <strong>and</strong> antioxidantis applied to the bare wire.CAUTIONTo ensure adequate bonding when attaching the ground lug, a minimum of 20 PSI of torque isrequired to be applied to the mounting hardware used to attach the ground lug.88 <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide53-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!