13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Installing a <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 16000 router 45. Tighten the screws to secure the router.NOTEFor better grounding of the router to the rack, attach the router using star washers. You can also usestar washers with single-hole grounding lugs to prevent rotation of the lug.6. Repeat step 2 through step 5 to mount each router in the rack.Installing <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 16000 modulesThe <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 16000 router ships with the required switch fabric modules installed.The procedure in this section applies to all modules. The sequence for installing multiple modulesis important to ensure proper fit. For the <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 16000 router, start with the lowestrow, <strong>and</strong> move upwards, installing modules from left to right.For instructions about installing 2x100GbE interface modules, refer to “Installing 2x100GbEinterface modules in <strong>Brocade</strong> <strong>MLX</strong> routers” on page 239.DANGERThe intra-building port or ports of the equipment or subassembly is suitable for connection tointra-building or unexposed wiring or cabling only. The intra-building port or ports of theequipment or subassembly MUST NOT be metallically connected to interfaces that connect to theoutside plant (OSP) or its wiring. These interfaces are designed for use as intra-buildinginterfaces only (Type 2 or Type 4 ports as described in GR-1089-CORE, Issue 5) <strong>and</strong> requireisolation from the exposed OSP cabling. The addition of Primary Protectors is not sufficientprotection in order to connect these interfaces metallically to OSP wiring.NOTE<strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> modules are dedicated, which means that you must install them in <strong>Brocade</strong><strong>NetIron</strong> <strong>XMR</strong> routers only. For example, if you install a <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> module in another<strong>Brocade</strong> router or install a module intended for another <strong>Brocade</strong> router in the <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong>router, the router <strong>and</strong> module will not function properly.Although management modules are designed to be hot-swappable, you must upgrade the softwareon all interface modules <strong>and</strong> management modules to the appropriate software release beforeinstalling them. For more information on the appropriate software release, refer to the <strong>Hardware</strong>Installation Notes that shipped with the management module.For information about how to disable <strong>and</strong> re-enable power to interface modules, see “Disabling <strong>and</strong>re-enabling power to interface modules” on page 321Table 42 identifies the slots where you install modules. Identification markings are located at thebase of each slot.TABLE 42Module<strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 16000 module installationSlot numberManagement modulesActive module – M1 (upper).Redundant module – M2 (lower).<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 26553-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!