13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Router modules 1Power supply requirements for NI-<strong>MLX</strong>-1Gx48-T-A modulesTable 21 lists the power supply requirements for each type of router when installingNI-<strong>MLX</strong>-1Gx48-T-A modules.TABLE 21Router typePower supply requirements for NI-<strong>MLX</strong>-1Gx48-T-A modulesNumber ofNI-<strong>MLX</strong>-1Gx48-T-Amodules installedPower supply requirements<strong>MLX</strong>e-4 one one 1200W PSUfor 1+1 redundancy, install two 1200W PSU<strong>MLX</strong>-4 <strong>and</strong><strong>Brocade</strong> <strong>NetIron</strong><strong>XMR</strong> 4000<strong>MLX</strong>e-8 <strong>and</strong><strong>Brocade</strong> <strong>NetIron</strong><strong>XMR</strong> 8000two to fourfourseveneighttwo 1200W PSUfor 2+2 redundancy, install four 1200W PSUone 1800W PSUfor 1+1 redundancy, install two 1800W PSUone 1200W PSUfor 1+1 redundancy, install two 1200W PSUtwo 1200W PSUfor 2+2 redundancy, install four 1200W PSUthree 1200W PSUfor 3+1 redundancy, install four 1200W PSUtwo 1800W PSUfor 2+3 redundancy, install four 1800W PSUAll 16-slot routers fifteen four 1200W PSUfor 4+4 redundancy, install eight 1200W PSUsixteenfive 1200W PSUfor 5+3 redundancy, install eight 1200W PSUfour 1800W PSUfor 4+4 redundancy, install eight 1800W PSUAll 32-slot routers twenty-eight four 2400W PSUfor 4+4 redundancy, install eight 2400W PSUtwenty-nine tothirty-twofive 2400W PSUfor 4+4 redundancy, install eight 2400W PSUfour 3000W PSUfor 4+4 redundancy, install 3000W PSUNOTEWhen one or more NI-<strong>MLX</strong>-1GX48-T-A modules are installed in an <strong>MLX</strong>16-slot router, you mustreplace the NI-X-16-FAN-EXH modules with NIBI-16-FAN-EXH-A high-speed fan modules. For moreinformation about high-speed fan modules, see “NIBI-16-FAN-EXH-A high-speed fan assemblies” onpage 61. If the 16-slot router is not upgraded to support NIBI-16-FAN-EXH-A modules beforeNI-<strong>MLX</strong>-1GX48-T-A modules are installed, the following Syslog message is displayed.SYSLOG: Mar 26 14:19:53:R1, 48X1G modules in slots 10,11,13,16 shouldn't berunning without high speed fans.NOTEThe NIBI-16-FAN-EXH-A fan module does not ship with <strong>Brocade</strong> <strong>MLX</strong>-16 routers. Contact <strong>Brocade</strong> topurchase this module.<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 4353-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!