2Installation precautionsCAUTIONEnsure that the router does not overload the power circuits, wiring, <strong>and</strong> over-current protection.To determine the possibility of overloading the supply circuits, add the ampere (amp) ratings of alldevices installed on the same circuit as the router. Compare this total with the rating limit for thecircuit. The maximum ampere ratings are usually printed on the routers near the input powerconnectors.CAUTION<strong>Brocade</strong> <strong>MLX</strong>e routers with DC power sources are intended for installation in restricted accessareas only. A restricted access area is where access can be gained only by service personnelthrough the use of a special tool, lock <strong>and</strong> key, or other means of security, <strong>and</strong> is controlled by theauthority responsible for the location.CAUTION<strong>Brocade</strong> <strong>MLX</strong>e routers with AC power sources are intended for installation in restricted accessareas only. A restricted access area is a location where access can be gained only by servicepersonnel through the use of a special tool, lock <strong>and</strong> key, or other means of security.CAUTIONFor the DC input circuit to the system of <strong>Brocade</strong> <strong>MLX</strong>e-4. <strong>Brocade</strong> <strong>MLX</strong>e-8, <strong>and</strong> <strong>Brocade</strong> <strong>MLX</strong>e-16routers (1800W supply), make sure there is a 60 amp circuit breaker, minimum -48VDC, doublepole, on the input lugs to the power supply. The input wiring for connection to the product shouldbe copper wire, 6 AWG, marked VW-1, <strong>and</strong> rated minimum 90 C.CAUTIONFor the DC input circuit to the system of <strong>Brocade</strong> <strong>MLX</strong>e-4. <strong>Brocade</strong> <strong>MLX</strong>e-8, <strong>and</strong> <strong>Brocade</strong> <strong>MLX</strong>e16routers (1200W supply), make sure there is a 40 amp circuit breaker, minimum -48VDC, doublepole, on the input lugs to the power supply. The input wiring for connection to the product shouldbe copper wire, 6 AWG, marked VW-1, <strong>and</strong> rated minimum 90 C.CAUTIONFor the DC input circuit to the system of a <strong>Brocade</strong> <strong>MLX</strong>e-32 router (3000W supply), make surethere is a 80 amp circuit breaker, minimum -48VDC, double pole, on the input lugs to the powersupply. The input wiring for connection to the product should be copper wire, 2 AWG, markedVW-1, <strong>and</strong> rated minimum 90 C.66 <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide53-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!