13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Managing the cooling system 7Displaying fan tray status <strong>and</strong> speedTo display the status <strong>and</strong> speed of the 4-speed fans in the router, enter the show chassis comm<strong>and</strong>at any level of the CLI.<strong>Brocade</strong># show chassis...--- FANS ---Back fan tray 1: Status = OK, Speed = LOW (50%)Back fan tray 2: Status = OK, Speed = LOW (50%)Back fan tray 3: Status = OK, Speed = LOW (50%)Back fan tray 4: Status = OK, Speed = LOW (50%)Syntax: show chassisFor information about all output generated by the show chassis comm<strong>and</strong>, refer to “Displayingdevice status <strong>and</strong> temperature readings” on page 324.TABLE 51FieldFan status <strong>and</strong> speed fieldsDescriptionStatusSpeedThe status can be one of the following:• OK – The fan is functioning properly <strong>and</strong> is keeping the temperature of each module withinan acceptable temperature range.• Failed – The fan is not functioning properly or the fan control module cannot control the fan.The speed can be one of the following:• LOW – The fan is functioning at 50 percent of capacity.• MEDIUM – The fan is functioning at 75 percent of capacity.• MEDIUM-HIGH – The fan is functioning at 90 percent of capacity.• HIGH – The fan is functioning at 100 percent of capacity.Displaying temperature warningsIf the temperature of a module exceeds the high temperature threshold for any of the fan speeds,the system sends a warning message to the system log <strong>and</strong> an SNMP trap. (For more informationabout the low <strong>and</strong> high temperature thresholds, refer to “Changing temperature thresholds formodules <strong>and</strong> fan speeds” on page 331.) This section describes how to view the system log. If youhave configured your router to use a Syslog server or SNMP trap receiver, refer to thedocumentation for the server or receiver.To display the system log, enter the show log comm<strong>and</strong> at any CLI level.<strong>Brocade</strong># show logSyntax: show logTemperature log reductionDepending on settings <strong>and</strong> temperature readings, fan speeds are changed dynamically within thefollowing ranges: low, med, med-hi, <strong>and</strong> high. Fan speed changes are determined by temperaturethresholds set for sensors on the management modules, interface modules <strong>and</strong> switch fabricmodules. When a temperature threshold is passed upward on any module, the fan speed changesto the assigned fan speed. This occurs even if the temperature is within the threshold for the slowerfan speed on other modules. In previous versions of the software, a log message is sent whenevera temperature threshold is crossed on any module whether the fan speed is actually increased ornot. This can result in excessive log messages.<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 33753-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!