Verifying proper operation 2TABLE 33 Router LED states <strong>and</strong> actions (Continued)LED label Desired state Meaning AbnormalstateMeaning or action10/100/1000Ethernet PortInterface moduleOn or blinking(yellow)The port istransmitting <strong>and</strong>receiving packets.Pwr On The module isreceiving power.Mgmt ActDuringinitialization:steady blinking.After initialization:occasionalblinking.The activemanagementmodule processor<strong>and</strong> the interfacemodule processorare communicating.Link On A link is establishedwith the remoteport.Active On or blinking The port istransmitting <strong>and</strong>receiving userpackets.Switch Fabric modulePwr On The module isreceiving power.Off for anextendedperiodOffOff for anextendedperiod.OffOff for anextendedperiod.OffThe port is not transmitting or receiving packets. Check thefollowing:• Look at the LED for the other 10/100/1000 Ethernet port tosee if a link has been established with the remote port.• Verify that the connection to the other router has beenproperly made. Also, make certain that the other router ispowered on <strong>and</strong> operating correctly.• Try using a different cable.The module is not receiving power. Check the following:• Make certain that the module is installed properly. For moreinformation, refer to the module installation section in thischapter that applies to your router model.• The module may not be receiving enough power. <strong>Brocade</strong>recommends installing power supplies in a fully redundantconfiguration as described for each router model in thischapter.• Check the Pwr LED on the management module. If it is on,the management module may be preventing power fromgetting to the interface module.• Enter the show chassis comm<strong>and</strong> at any level of the CLI todetermine if the management module recognizes thepresence of all power sources.• If you are using AC power supplies, see the entry for the ACpower supply LED in this table for more information.The interface module may be in interactive mode. Check thestatus of the module by entering the show module comm<strong>and</strong> atany level of the CLI.This LED will remain off until you have cabled the interfacemodule ports.After cabling the ports, if this LED is still off, a link is notestablished with the remote port. For more information, refer toTable 45 on page 319.This LED will remain off until you have cabled the interfacemodule ports.After cabling the ports, if this LED is still off, the port is nottransmitting or receiving user packets. For more information,refer to Table 45 on page 319.The module is not receiving power. Check the following:• Make certain that the module is installed properly. For moreinformation, refer to the module installation section in thischapter that applies to your router model.• If you are using AC power supplies, refer to the AC powersupply LED information in this table for more information.<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 14353-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!