Installing a <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 8000 router 4CAUTIONTo ensure adequate bonding when attaching the ground lug, a minimum of 20 PSI of torque isrequired to be applied to the mounting hardware used to attach the ground lug.FIGURE 183Crimping the power supply wire in the lug11 AWG power supply wire:#8 AWG wire for 1200 W power supply#6 AWG wire for 1800 W power supply5. Connect the -48V cable to the negative terminal <strong>and</strong> the 0V cable to the positive terminal asmarked on the power supply.NOTEDC return must be isolated from the device ground (DC-I) when connecting to the power supply.6. Replace the transparent cover.This equipment installation must meet NEC/CEC code requirements. Consult local authorities forregulations.Final stepsFollow these steps to complete the installation:• “Attaching a management station”• “Activating the power source”• “Verifying proper operation”<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 26153-1002373-02