7Managing the cooling systemChanging the temperature polling intervalBy default, the router reads the temperature sensor on each module every 60 seconds. To changethe polling interval, enter the temp-poll-period comm<strong>and</strong> at the global CONFIG level of the CLI.<strong>Brocade</strong>(config)# temp-poll-period 120Syntax: temp-poll-period For the parameter, you can specify a value from 30 – 120.NOTEAdjusting temperature polling interval out of the default setting can negatively affect the efficientcooling of blades <strong>and</strong> may cause a blade to overheat <strong>and</strong> shutdown.Manually setting the fan speedTypically, the management module, in conjunction with default settings of low <strong>and</strong> hightemperature thresholds, determines the speed of the two four-speed fans. (For information aboutchanging the low <strong>and</strong> high temperature thresholds, refer to “Changing temperature thresholds formodules <strong>and</strong> fan speeds” on page 331.) You can manually set the fan speed using theset-fan-speed comm<strong>and</strong> in the Global CONFIG level of the CLI.NOTEAuto control of fan speed is not monitored when cards are in interactive mode. Set fan speed to highto prevent over-temp condition.NOTESetting a value other than auto or high disables auto fan control <strong>and</strong> will negatively affect theefficient cooling of blades <strong>and</strong> may cause a blade to overheat <strong>and</strong> shutdown.For example, to set the speed of fan 0 to medium-high, enter the following comm<strong>and</strong>.<strong>Brocade</strong># set-fan-speed med-highSyntax: set-fan-speed For the parameter, you can specify the following:• auto – The system is adjusted by the monitoring system.• high – The system sets the fan speed to high.• low – The system sets the fan speed to low.• med – The system sets the fan speed to medium.• med-high – The system sets the fan speed to medium-high.Monitoring the cooling systemYou can monitor the following aspects of the router cooling system:• The temperature of the fan control modules• The status <strong>and</strong> speed of the fans• The temperature warnings sent to the system log <strong>and</strong> that generate an SNMP trap336 <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide53-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!