13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installing a <strong>Brocade</strong> <strong>MLX</strong>e-16 router 2CAUTIONFor the NEBS-compliant installation of <strong>Brocade</strong> <strong>MLX</strong>e-4, <strong>Brocade</strong> <strong>MLX</strong>e--8, <strong>and</strong> <strong>Brocade</strong> <strong>MLX</strong>e-16routers with AC <strong>and</strong> DC systems, use a ground wire of at least 6 American Wire Gauge (AWG). Theground wire should have an agency-approved crimped connector (provided with the device)attached to one end, with the other end attached to building ground. The connector must becrimped with the proper tool, allowing it to be connected to both ground screws on the enclosure.Before crimping the ground wire into the provided ground lug, ensure the bare copper wire hasbeen cleaned <strong>and</strong> antioxidant is applied to the bare wire.CAUTIONFor the NEBS-compliant installation of <strong>Brocade</strong> <strong>MLX</strong>e-32, routers with AC <strong>and</strong> DC systems, use aground wire of at least 2 American Wire Gauge (AWG). The ground wire should have anagency-approved crimped connector (provided with the device) attached to one end, with theother end attached to building ground. The connector must be crimped with the proper tool,allowing it to be connected to both ground screws on the enclosure. Before crimping the groundwire into the provided ground lug, ensure the bare copper wire has been cleaned <strong>and</strong> antioxidantis applied to the bare wire.CAUTIONTo ensure adequate bonding when attaching the ground lug, a minimum of 20 PSI of torque isrequired to be applied to the mounting hardware used to attach the ground lug.FIGURE 63Crimping the power supply wire in the power lug11 AWG power supply wire:#8 AWG power supply wire for 1200W power supplies#6 AWG power supply wire for 1800W power supplies4. Connect the -48V cable to the negative terminal <strong>and</strong> the 0V cable to the positive terminal onthe power supply.NOTEDC return must be isolated from the router ground (DC-I) when connecting to the power supply.5. Replace the transparent cover.This equipment installation must meet NEC/CEC code requirements. Consult local authorities forregulations.<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 9953-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!