13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

4Verifying proper operationThe Status column shows the module status. The management module status can be one of thefollowing:• ACTIVE – The module is currently the active management module.• STANDBY – The module is currently the st<strong>and</strong>by management module.• COMING UP – The module is coming up as the st<strong>and</strong>by module. This status occurs if thest<strong>and</strong>by management module becomes the active module during a switchover.The switch fabric module status can be one of the following:• ACTIVE – The module is up <strong>and</strong> running.• BAD – The management module cannot initialize the switch fabric module.An interface module status can be one of the following:• CARD_STATE_INIT – The system detects the module but the module is not up <strong>and</strong> running yet.• CARD_STATE_BOOT – The module is booting.• CARD_STATE_INTERACTIVE – The module is booting from interactive mode.• CARD_STATE_LP_SYNC – The software images are synchronized between the managementmodule <strong>and</strong> interface module.• CARD_STATE_SYNC – The system is currently synchronizing the software image between themanagement module <strong>and</strong> interface module.• CARD_STATE_SOFTWARE_LOADED – The module has loaded the software image.• CARD_STATE_POWER_OFF – The module does not have power.• CARD_STATE_UP – The module is operating normally.• CARD_STATE_FAILED – The management module was unable to bring up an interface module.If you see this status, make certain that the interface module is installed properly. For moreinformation, refer to “Installing <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 4000 modules” on page 245, “Installing<strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 8000 modules” on page 255, “Installing <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 16000modules” on page 265, or “Installing <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 32000 modules” on page 277.• CARD_DOWN_REASON_ – The module is in a nonfunctional state. This statusappears with an explanation for why the module is down. For example,“CARD_DOWN_REASON_BOOT_FAILED.” If the explanation does not help you resolve theproblem, contact technical support <strong>and</strong> provide the explanation included with this status.302 <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide53-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!