13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

7Managing interface modulesThe default behavior is a for log message to be sent only when the fan speed is actually changed,which reduces the number of messages. A CLI option allows you to log all messages or have asingle log message sent when any temperature threshold is crossed.Details about how to set temperature thresholds <strong>and</strong> default threshold values are described in the“Configuring the cooling system” on page 331Configuring temperature loggingThe temp log-threshold comm<strong>and</strong> sets the temperature logging threshold to send a single messagewhenever any of the thresholds are crossed.<strong>Brocade</strong>(config) temp-log-threshold lowSyntax: temp-log-threshold [verbose | high | low | med | med-high]• The verbose option generates logs whenever a temperature threshold is crossed. This is theoperational mode of previous versions of Multi-Service IronWare software <strong>and</strong> providesbackward compatibility.• The high option generates logs only when the high threshold is crossed.• The low option generates logs whenever any threshold (low, medium, medium-high or high) iscrossed.• The med option generates logs only when the medium, medium-high, <strong>and</strong> high thresholds arecrossed.• The med-high option generates logs only when the medium-high <strong>and</strong> high thresholds arecrossed. This is the default setting.This output displays two instances of a module temperature exceeding the warning threshold.Managing interface modulesConfiguring interface module boot parametersEthernet interface modules contain independent copies of system software <strong>and</strong> boot after themanagement module boots. By default, the following boot-related events occur:• The router synchronizes, or prompts you to synchronize, the software image on the interfacemodules with the software on the management module.• Interface modules boot from a source specified by the management module (the defaultsource is a primary image in the flash memory on the interface module.)You can make these changes:• Disable the synchronization of images between the management module <strong>and</strong> all interfacemodules. You can also initiate an immediate synchronization.• Change the boot source of one or all interface modules.Synchronizing the software image between management modules <strong>and</strong> interfacemodulesAn interface module can have primary <strong>and</strong> secondary images that reside in the flash memory.338 <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide53-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!