13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installing a <strong>Brocade</strong> <strong>MLX</strong>-8 router 3NOTEBecause there are multiple power supply vendors, the LED layout on your DC power supply may differfrom what is shown in Figure 123. However, the LED functions are identical.Follow these steps to connect a DC power source.1. Use a #1 Phillips screwdriver to remove the two screws that hold the transparent cover overthe power supply lugs, as shown in Figure 123.FIGURE 123The <strong>Brocade</strong> <strong>MLX</strong>-8 DC power supply2DC INDC OUT ALM11 Screws holding transparent cover 2 Power lug screws2. Use a #2 Phillips screwdriver to remove the power lugs.3. Crimp #8 AWG power supply wire into the power lugs <strong>and</strong> reconnect the lugs to the powersupply unit. Refer to Figure 124.CAUTIONFor the NEBS-compliant installation of <strong>Brocade</strong> <strong>MLX</strong>e-4, <strong>Brocade</strong> <strong>MLX</strong>e--8, <strong>and</strong> <strong>Brocade</strong> <strong>MLX</strong>e-16routers with AC <strong>and</strong> DC systems, use a ground wire of at least 6 American Wire Gauge (AWG). Theground wire should have an agency-approved crimped connector (provided with the device)attached to one end, with the other end attached to building ground. The connector must becrimped with the proper tool, allowing it to be connected to both ground screws on the enclosure.Before crimping the ground wire into the provided ground lug, ensure the bare copper wire hasbeen cleaned <strong>and</strong> antioxidant is applied to the bare wire.CAUTIONFor the NEBS-compliant installation of <strong>Brocade</strong> <strong>MLX</strong>e-32, routers with AC <strong>and</strong> DC systems, use aground wire of at least 2 American Wire Gauge (AWG). The ground wire should have anagency-approved crimped connector (provided with the device) attached to one end, with theother end attached to building ground. The connector must be crimped with the proper tool,<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 17353-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!