4Installing a <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 8000 routeror Type 4 ports as described in GR-1089-CORE, Issue 5) <strong>and</strong> require isolation from the exposedOSP cabling. The addition of Primary Protectors is not sufficient protection in order to connectthese interfaces metallically to OSP wiring.NOTE<strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> modules are dedicated, which means that you must install them in a <strong>Brocade</strong><strong>NetIron</strong> <strong>XMR</strong> router only. For example, if you install the <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> module in another<strong>Brocade</strong> device or install a module intended for another <strong>Brocade</strong> device in the <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong>router, the router <strong>and</strong> module will not function properly.Although management modules are designed to be hot-swappable, you must upgrade the softwareon all interface modules <strong>and</strong> management modules to the appropriate software release beforeinstalling them. For more information on the appropriate software release, refer to the <strong>Hardware</strong>Installation Notes that shipped with the management module.For information about how to disable <strong>and</strong> re-enable power to interface modules, see “Disabling <strong>and</strong>re-enabling power to interface modules” on page 321Table 41 provides the slot numbers where you can install modules. Identification marks appear athe base of each slot.TABLE 41Module<strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 8000 module installationSlot numberManagement modulesActive module – M1 (left).Redundant module – M2 (right).1 – 8 Interface modulesSF1 – SF3Switch fabric modulesThe <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> 8000 router ships with slot blanks installed in all empty module slots.The slot blanks cover empty slots, ensuring proper airflow within the router. Before you install amodule in a slot, you must remove the slot blank.CAUTIONIf you do not install a module in a slot, you must keep the slot blank in place. If you operate therouter with an uncovered slot, the system may overheat. Tighten the screws that secure the slotblanks so that they remain in place when removing adjacent panels or modules.Although slot blanks differ in size, the procedure for removing them is the same. You will need aflat-blade screwdriver to perform this task.Follow the steps to remove a slot blank.1. Loosen the screws on either end of the slot blank by h<strong>and</strong> or with a flat blade screwdriver.2. Pull the slot blank out of the router, <strong>and</strong> store it in a safe place for future use.NOTEIf you are installing a redundant management module, refer to <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong><strong>NetIron</strong> Family Configuration Guide, Chapter 8: Using a Redundant Management Module, forinformation about how the redundant module works, optional software configurations, <strong>and</strong> how tomanage redundancy.256 <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide53-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!