13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Installing a <strong>Brocade</strong> <strong>MLX</strong>-32 router 3or Type 4 ports as described in GR-1089-CORE, Issue 5) <strong>and</strong> require isolation from the exposedOSP cabling. The addition of Primary Protectors is not sufficient protection in order to connectthese interfaces metallically to OSP wiring.CAUTIONIf you do not install a module in a slot, you must leave the slot blank installed in the slot. If youoperate the router with an uncovered slot, the system may overheat.NOTE<strong>Brocade</strong> <strong>MLX</strong> modules are dedicated, which means that you must install them in the <strong>Brocade</strong> <strong>MLX</strong>routers only. If you install a <strong>Brocade</strong> <strong>MLX</strong> module in another <strong>Brocade</strong> device or install a moduleintended for another <strong>Brocade</strong> device in a <strong>Brocade</strong> <strong>MLX</strong> router, the router <strong>and</strong> module will notfunction properly.Although management modules are designed to be hot-swappable, you must upgrade the softwareon all interface modules <strong>and</strong> management modules to the appropriate software release beforeinstalling them. For more information on the appropriate software release, refer to the <strong>Hardware</strong>Installation Notes that shipped with the management module.If you are installing a redundant management module, refer to the chapter titled “Using aRedundant Management Module” in the <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> FamilyConfiguration Guide for information about how the redundant module works, optional softwareconfigurations that you can perform, <strong>and</strong> how to manage the redundancy feature.For information about how to disable <strong>and</strong> re-enable power to interface modules, see “Disabling <strong>and</strong>re-enabling power to interface modules” on page 321Before installing modules in the <strong>Brocade</strong> <strong>MLX</strong>-32 router, have the following items available:• A large flat-blade screwdriver.• An ESD wrist strap with a plug for connection to the ESD connector on the <strong>Brocade</strong> <strong>MLX</strong>-32router.DANGERFor safety reasons, the ESD wrist strap should contain a 1 megohm series resistor.CAUTIONIf you are hot-swapping a module, allow a minimum of two seconds after a module (or powersupply or fan tray) has been removed before inserting a module in the same slot.Follow this procedure to install a module in the <strong>Brocade</strong> <strong>MLX</strong> router.1. If you are installing a module into a slot which may have been configured for a different moduletype, remove the old configuration information by following these steps:<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 21153-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!