Replacing a power supply 8NOTEA threshold value of 0 will not automatically shutdown a power supply due to failures.For Syslog messages, please refer to Appendix A, Using Syslog in the <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong><strong>Brocade</strong> <strong>NetIron</strong> Family Configuration Guide.Clearing power supply failure timestampsUse the power-supply monitoring clear comm<strong>and</strong> to clear all collected failure timestamps for agiven power supply, or for all available power supplies.To clear all collected failure timestamps for a power supply, enter the following comm<strong>and</strong>.<strong>Brocade</strong>(config)# power-supply monitoring clear 1This will clear all collected failure timestamps for the Power Supply # 1Are you sure? (enter 'y' or 'n'): yTo clear all collected failure timestamps for all available power supplies, enter the followingcomm<strong>and</strong>.<strong>Brocade</strong>(config)# power-supply monitoring clear allThis will clear all collected failure timestamps for all available Power SuppliesAre you sure? (enter 'y' or 'n'): yYou are asked to verify this comm<strong>and</strong> by entering “yes” or “no.Syntax: power-supply monitoring clear ]By default, no power-supply monitoring is configured.The variable specifies a power supply number, The all keyword clears all available powersupplies.Displaying power supply monitoring timestampsTo display timestamps for failures on any power supply, enter the following comm<strong>and</strong>.<strong>Brocade</strong># show power-supply-monitoringPS-1 PS-2 PS-3 PS-4 PS-5 PS-6 PS-7 PS-81 ) 0 0 0 0 0 0 0 02 ) 0 0 0 0 0 0 0 03 ) 0 0 0 0 0 0 0 04 ) 0 0 0 0 0 0 0 05 ) 0 0 0 0 0 0 0 06 ) 0 0 0 0 0 0 0 07 ) 0 0 0 0 0 0 0 08 ) 0 0 0 0 0 0 0 09 ) 0 0 0 0 0 0 0 0The show power-supply-monitoring comm<strong>and</strong> displays the last 32 recorded failure timestamps fora power supply. The current configured power supply monitoring threshold value is also displayedat the end of the output.Syntax: show power-supply-monitoring<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 35553-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!