13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Verifying proper operation 3Insert the other end of each cable into a wall outlet. The following rules apply:• 1200W power supplies require 115V/120V outlets.• 1800W power supplies require 200V-240V for full power or are limited to 1200W with115V/120V outlets.• 2400W <strong>and</strong> 3000W power supplies require high line (200V-240V) outlets.DANGERIf the installation requires a different power cord than the one supplied with the device, makesure you use a power cord displaying the mark of the safety agency that defines the regulationsfor power cords in your country. The mark is your assurance that the power cord can be usedsafely with the device.NOTEBecause the router is designed to provide uninterrupted service even when you insert orremove management modules <strong>and</strong> interface modules, there is no on/off power switch. To turnthe system off, simply unplug the power cords.NOTEWall outlets should be installed near the equipment <strong>and</strong> should be easily accessible.4. Verify that the router has initialized successfully. Refer to “Verifying proper operation” onpage 229.Verifying proper operationTo verify that your router is operating properly, observe the LEDs, or display the status of themodules using the CLI.Observing the LEDsWhen power is supplied to the router, you can observe the LEDs to verify that the router initializedsuccessfully. Table 39 describes the LEDs, the desired state of each LED, possible abnormal statesof each LED, <strong>and</strong> what to do if an LED indicates an abnormal state.TABLE 39Router LED states <strong>and</strong> actionsLED label Desired state Meaning AbnormalstateMeaning or actionManagement moduleActiveThe Active LED onone of the installedmanagementmodules should beon.The module isfunctioning as theactive managementmodule.OffNeither of the management modules is managing the switchfabric <strong>and</strong> interface modules. A problem may have occurredduring initialization. Check your attached PC or terminal forpossible error messages.<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 22953-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!