13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

3Installing a <strong>Brocade</strong> <strong>MLX</strong>-8 routerFor information about how to disable <strong>and</strong> re-enable power to interface modules, see “Disabling <strong>and</strong>re-enabling power to interface modules” on page 321DANGERThe intra-building ports of the equipment or subassembly are suitable for connection tointra-building or unexposed wiring or cabling only. The intra-building ports of the equipment orsubassembly MUST NOT be metallically connected to interfaces that connect to the outside plant(OSP) or its wiring. These interfaces are designed for use as intra-building interfaces only (Type 2or Type 4 ports as described in GR-1089-CORE, Issue 5) <strong>and</strong> require isolation from the exposedOSP cabling. The addition of Primary Protectors is not sufficient protection in order to connectthese interfaces metallically to OSP wiring.NOTE<strong>Brocade</strong> <strong>MLX</strong> modules are dedicated, which means that you must install them in the <strong>Brocade</strong> <strong>MLX</strong>router only. If you try to install a <strong>Brocade</strong> <strong>MLX</strong> module in another <strong>Brocade</strong> device, or install a moduleintended for a another <strong>Brocade</strong> device in a <strong>Brocade</strong> <strong>MLX</strong> router, the router <strong>and</strong> module will notfunction properly.Although management modules are designed to be hot-swappable, you must upgrade the softwareon all interface modules <strong>and</strong> management modules to the appropriate software release beforeinstalling them. For more information on the appropriate software release, refer to the <strong>Hardware</strong>Installation Notes that shipped with the management module.If you are installing a redundant management module, refer to the chapter titled “Using a RedundantManagement Module” in the <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> Family Configuration Guidefor information about how the redundant module works, optional software configurations, <strong>and</strong> howto manage redundancy.Table 35 identifies the router slot numbers where the modules must be installed. An identifyinglabel can be seen at the base of each slot.TABLE 35Module<strong>Brocade</strong> <strong>MLX</strong>-8 module slot designationsSlot numberManagement modulesActive module – M1 (left).Redundant module – M2 (right).Interface modules 1 – 8Switch fabric modulesSF1 – SF3CAUTIONIf you do not install a module in a slot, you must leave the slot blank installed in the slot. If yourun the router with an uncovered slot, the system may overheat.Before installing a module in the <strong>Brocade</strong> <strong>MLX</strong>-8 router, have the following items available:• A large flat-blade screwdriver.168 <strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide53-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!