13.07.2015 Views

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

Brocade MLX Series and Brocade NetIron XMR Hardware ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Attaching a management station 3Removing <strong>Brocade</strong> <strong>MLX</strong>-32 router DC power suppliesFollow these steps to remove a 2400W DC power supply in a <strong>Brocade</strong> <strong>MLX</strong>-32 router:1. Ensure the main DC power breaker is OFF.2. Use a #1 Phillips screwdriver to remove screw that secures the safety cover, as shown inFigure 161 on page 225. Remove the safety cover.3. Use a #2 Phillips screwdriver to remove the screws securing the power lugs. Refer toFigure 162 on page 225.4. Pull down on h<strong>and</strong>le to remove power supply. Refer to Figure 159 on page 223.Follow these steps to remove a 3000W DC power supply in a <strong>Brocade</strong> <strong>MLX</strong>-32 router:1. Ensure the main DC power breaker is OFF.2. Use a #1 Phillips screwdriver to remove the screw that secures the safety cover, as shown inFigure 161 on page 225.3. Pull down on the h<strong>and</strong>le to remove the 3000W power supply. Refer to Figure 159 on page 223.4. Use a #2 Phillips screwdriver to remove the screws securing the power lugs. Refer toFigure 162 on page 225.Final stepsComplete these steps in the order in which they are listed:• “Attaching a management station”• “Activating the power source”• “Verifying proper operation”Attaching a management stationYou can manage your router in the following ways:• Connect a PC or terminal to the console port on the management module. From this port, youcan assign an IP address to the management module <strong>and</strong> establish connections throughTelnet or SSH.• Connect the router to your existing management network <strong>and</strong> manage the router <strong>and</strong> othernetwork devices from a management station.NOTEThe management network that you connect to through the 10/100 Ethernet port must beseparate <strong>and</strong> isolated from the network over which user packets are switched <strong>and</strong> routed. Forinformation about functionality on the management port, Refer to “Underst<strong>and</strong>ingmanagement port functions” on page 317.<strong>Brocade</strong> <strong>MLX</strong> <strong>Series</strong> <strong>and</strong> <strong>Brocade</strong> <strong>NetIron</strong> <strong>XMR</strong> <strong>Hardware</strong> Installation Guide 22753-1002373-02

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!